Estimation of Fan Beam and Parallel Beam Parameters in a Wire Mesh Design
Open Access
- 11 January 2012
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 40 (1) , 37-43
Abstract
Special collimators used in imaging systems play an important part in obtaining qualified images to improve diagnosis in medicine. Methods: The primary aim of this study was to compare resolution between fan beam and parallel beam collimators using Monte Carlo simulation in the shape of cubic holes. Also, parameters such as geometric efficiency, geometric resolution, scatter, penetration, and full width at half maximum were studied to compare their special characteristics. Results: The simulation results demonstrated that the geometry efficiency of a fan beam collimator increased as the angle of the slant hole increased, and the geometric resolution decreased as the angle of the slant hole increased, at a distinct distance from a monoenergetic source of γ-rays. In contrast, at a distinct angle, geometric resolution increased as the distance between the source and the collimator surface increased. For both collimators, scatter and penetration decreased as the distance increased. These results were in agreement with ADAC company data. Finally, fan beam collimators were found to have better resolution than parallel beam collimators with a cubic hole shape in a wire mesh design. Conclusion: Estimation of the fan beam by parallel beam parameters as cubic holes can be suitable in collimator design to improve resolution and efficiency.Keywords
This publication has 16 references indexed in Scilit:
- Characteristics of Multihole Collimator Gamma Camera Simulation Modeled Using MCNP5AIP Conference Proceedings, 2008
- A comparative study on improving image resolution of the multihole collimator gamma camera modelled by the MCNPX code using the Wiener filtering technique2005
- Modeling of the sensitivity of fan-beam collimation in SPECT imaging2005
- Importance of the choice of the collimator for the detection of small lesions in scintimammography: a phantom studyPhysics in Medicine & Biology, 2001
- Simulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffman brain phantom: Collimator and filter selection in SPECT neuroimagingAnnals of Nuclear Medicine, 1996
- Physically realistic Monte Carlo simulation of source, collimator and tomographic data acquisition for emission computed tomographyPhysics in Medicine & Biology, 1992
- The geometric transfer function for cone and fan beam collimatorsPhysics in Medicine & Biology, 1990
- Estimation of geometrical parameters for fan beam tomographyPhysics in Medicine & Biology, 1987
- The geometric transfer function component for scintillation camera collimators with straight parallel holesPhysics in Medicine & Biology, 1980
- The design of collimators for radioisotope scanningPhysics in Medicine & Biology, 1969