Restrictions in the use of correlation coefficients in comparing methods for the determination of the micronutrients in soils
- 1 June 1998
- journal article
- research article
- Published by Taylor & Francis in Communications in Soil Science and Plant Analysis
- Vol. 29 (11-14) , 1961-1972
Abstract
Fifty nine soil samples from the State of São Paulo were collected from the plow layer, with about half of these samples presenting low or medium concentrations of micronutrients. Micronutrients were extracted by one of the following solutions: DTPA at pH 7.3, DTPA at pH 5.3, Mehlich‐1 BR, Mehlich‐1 USA, Mehlich‐3, and 0.01 mol L‐1 calcium chloride (CaCl2), and then determined by inductively coupled plasma emission spectrometry (ICP‐AES). Simple linear correlations were calculated for the results of all methods against the DTPA method at pH 7.3. Two sets of calculations were always considered: one including all 59 soil samples and another set including only those samples containing low and medium amounts for each element. Higher correlation coefficients were observed when samples with high contents were included. For example, the range of correlations (R2) obtained for zinc (Zn) varied from 0.41 to 0.98, if all samples were considered in the calculations, but the range decreased to 0.41 ‐ 0.55 if samples with high contents of Zn were not considered. The correlation coefficients for CaCl2‐extractable Zn were not significant. The correlation coefficient (R2) range for copper (Cu) from 0.83 to 0.94 for all samples, decreased to 0.66 ‐ 0.72 with the exclusion of the samples with higher Cu contents. For manganese (Mn), the range of correlation coefficients (R2) varied from 0.74 to 0.92 for all samples but was reduced to 030 ‐ 0.50 when the samples with high contents of Mn were excluded. In the case of iron (Fe), the DTPA method at pH 5.3 presented results close to DTPA at pH 7.3 (R2 = 0.92), while the CaCl2 procedure had the poorest correlation (R2 = 0.42). In conclusion, the substitution of an extraction procedure based only in the correlation coefficients between methods may be misleading if the interest is diagnoses in the deficiency range.Keywords
This publication has 14 references indexed in Scilit:
- Iron availability in peat substrates as assessed by water, calcium chloride, ammonium acetate, DTPA and calcium chloride/DTPACommunications in Soil Science and Plant Analysis, 1996
- Efficiency of multinutrient extractants for the determination of available copper in soilsCommunications in Soil Science and Plant Analysis, 1996
- Efeito da reação do solo no zinco extraído pelas soluções de dtpa e Mehlich-1Bragantia, 1996
- Comparison of different methods for determination of phosphorus in calcium chloride extracts for prediction of availability to plantsCommunications in Soil Science and Plant Analysis, 1995
- Comparison of mehlich 1‐, 2‐, and 3‐, calcium chloride‐, bray‐, olsen‐, enger‐, and schachtschabel‐extractants for determinations of nutrient in two soil typesCommunications in Soil Science and Plant Analysis, 1994
- AB‐DTPA cation extraction in Spanish soil samplesCommunications in Soil Science and Plant Analysis, 1993
- Mehlich 3 soil test extractant: A modification of Mehlich 2 extractantCommunications in Soil Science and Plant Analysis, 1984
- Comparison of Chelating Agents as Extractants for Metals in Diverse Soil MaterialsSoil Science Society of America Journal, 1984
- Development of a DTPA Soil Test for Zinc, Iron, Manganese, and CopperSoil Science Society of America Journal, 1978
- STUDIES ON SOIL COPPER I. THE FRACTIONATION OF COPPER IN SOILSEuropean Journal of Soil Science, 1973