UniLine RetroFit: a multicenter observational cohort study on the effectiveness, safety, and durability of UniLine (an epoxy-treated xenopericardial valve) in patients with isolated aortic and mitral valve disease: rationale, objectives, and study design
Open Access
- 26 March 2025
- journal article
- Published by Kemerovo State Medical University in Fundamental and Clinical Medicine
- Vol. 10 (1) , 56-63
Abstract
Aim. To evaluate the effectiveness, safety, durability, and long-term outcomes of UniLine prosthetic valve application in patients with isolated mitral or aortic valve disease who have undergone a surgical valve replacement.Materials and Methods. The study aims to include at least 2,000 patients from seven Russian research centers who have undergone surgical mitral valve replacement or surgical aortic valve replacement using an epoxy-treated, xenopericardial bioprosthetic valve UniLine. The multicenter design of the study enhances patient recruitment, ensures a representative sample, minimises selection bias, and improves the generalisability of findings to the population. Currently, 989 patients have been enrolled, with ongoing recruitment, telephone follow-ups, and clinical assessments.Results. The primary endpoint is long-term safety and durability of UniLine valve in patients with isolated mitral or aortic valve disease, with the follow-up period up to 12 years postimplantation. The long-term safety will be assessed by the rates of valve-related complications including mortality, chronic heart failure, life-threatening bleeding, valve migration, valve thrombosis, any other valve-related complication requiring re-intervention, access site-related complications, acute coronary syndrome or progression of chronic coronary syndrome to the state requiring percutaneous coronary intervention or coronary artery bypass graft surgery, and stroke. Long-term durability will be evaluated via hemodynamic valve performance (maximum and mean pressure gradient across the atrioventricular prosthesis and effective orifice area, per manufacturer specifications) measured by echocardiography. Secondary endpoints are incidence of adverse event, major adverse events, device-related adverse events, procedure-related adverse events, and all-cause mortality.Conclusion. The UniLine RetroFit multicenter observational cohort study is a valuable initiative for obtaining real-world clinical data on the effectiveness, safety, durability, and long-term outcomes of UniLine valve in patients with isolated mitral and aortic valve disease.Keywords
This publication has 16 references indexed in Scilit:
- BIOLOGICAL PROSTHESES FOR CARDIOVASCULAR SURGERY – A HALF-CENTURY HISTORY AND DEVELOPMENT PROSPECTSComplex Issues of Cardiovascular Diseases, 2024
- Phenotype of a modern patient with valvular heart diseases: literature reviewCardiosomatics, 2023
- National Trends in TAVR and SAVR for Patients With Severe Isolated Aortic StenosisJACC, 2022
- "Portrait" of patients with pulmonary hypertension, associated with mitral valve diseases before cardiac surgeryComplex Issues of Cardiovascular Diseases, 2021
- THE USE OF TISSUE PROSTHESIS FOR MITRAL VALVE REPLACEMENT: POSSIBILITY OF DISCONTINUATION OF ANTICOAGULATIONComplex Issues of Cardiovascular Diseases, 2018
- Bioprosthetic Heart Valves, Thrombosis, Anticoagulation, and Imaging SurveillanceJACC: Cardiovascular Interventions, 2017
- SERIAL CHANGES IN THE LEVELS OF MATRIX METALLOPROTEINASE-3, -9, THEIR INHIBITORS AND INDICATORS OF MYOCARDIAL REMODELING IN PATIENTS WITH ACQUIRED HEART DISEASE UNDERGOING MITRAL VALVE REPLACEMENTComplex Issues of Cardiovascular Diseases, 2017
- COMPARISON OF THE LIFE QUALITY WITH MECHANICAL AND BIOLOGICAL MITRAL PROSTHESESRussian Journal of Cardiology, 2015
- Evaluation of proinflammatory status in recipients of biological prosthetic heart valvesRussian Heart Journal, 2015
- Selection of Valve ProsthesesSeminars in Thoracic and Cardiovascular Surgery, 2015