Measurement of 3-hydroxyisovaleric acid in urine from marginally biotin-deficient humans by UPLC-MS/MS
- 3 September 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (9) , 2805-2810
Abstract
Measurement of 3-hydroxyisovaleric acid (3HIA) in human urine has been shown to be a useful indicator of biotin status for a variety of clinical situations, including pregnancy. The work described herein presents a novel UPLC-MS/MS method for accurate and precise quantitation of urinary 3HIA. This method utilizes sample preparation prior to quantitation that has been simplified compared to the previous GC-MS method. To demonstrate the suitability of the UPLC-MS/MS method for human bio-monitoring, this method was used to measure 3-HIA in 64 human urine samples from eight healthy adults in whom marginal biotin deficiency had been induced experimentally by egg white feeding. 3HIA was detected in all specimens; the mean concentration [±standard deviation (SD)] was 80.6 ± 51 μM prior to inducing biotin deficiency. Mean excretion rate for 3HIA (expressed per mol urinary creatinine) before beginning the biotin-deficient diet was 8.5 ± 3.2 mmol 3HIA per mol creatinine and the mean increased threefold with deficiency. These specimens had been previously analyzed by GC-MS; the two data sets showed strong linear relationship with a correlation coefficient of 0.97. These results provide evidence that this method is suitable for bio-monitoring of biotin status in larger populations. Excretion of 3HIA in human urine before (Day 0) and after (Day 28) induction of marginal biotin deficiency by egg white feeding. NR denotes normal rangeKeywords
This publication has 25 references indexed in Scilit:
- Urinary Excretion of 3-Hydroxyisovaleryl Carnitine Is an Early and Sensitive Indicator of Marginal Biotin Deficiency in Humans,The Journal of Nutrition, 2011
- Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humansThe American Journal of Clinical Nutrition, 2010
- Quantitative Measurement of Urinary Excretion of 3-Hydroxyisovaleryl Carnitine by LC−MS/MS as an Indicator of Biotin Status in HumansAnalytical Chemistry, 2010
- Quantitative Measurement of Plasma 3-Hydroxyisovaleryl Carnitine by LC-MS/MS as a Novel Biomarker of Biotin Status in HumansAnalytical Chemistry, 2010
- Marginal Biotin Deficiency is Common in Normal Human Pregnancy and Is Highly Teratogenic in MiceThe Journal of Nutrition, 2009
- Determination of 3-hydroxyisovalerylcarnitine and other acylcarnitine levels using liquid chromatography–tandem mass spectrometry in serum and urine of a patient with multiple carboxylase deficiencyJournal of Chromatography B, 2008
- Marginal biotin deficiency is teratogenic in mice and perhaps humans: a review of biotin deficiency during human pregnancy and effects of biotin deficiency on gene expression and enzyme activities in mouse dam and fetusThe Journal of Nutritional Biochemistry, 2005
- Marginal Biotin Deficiency Is TeratogenicProceedings of the Society for Experimental Biology and Medicine, 2000
- Teratogenic effects of maternal biotin deficiency on mouse embryos examined at midgestationTeratology, 1990
- Quantification of urinary 3-hydroxyisovaleric acid using deuterated 3-hydroxyisovaleric acid as internal standardJournal of Mass Spectrometry, 1989