A semi-automated method using interpolation and optimisation for the 3D reconstruction of the spine from bi-planar radiography: a precision and accuracy study
Authors:
- 14 September 2007
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 46 (1) , 85-92
Abstract
The 3D reconstruction of the spine in upright posture can be obtained by bi-planar radiographic methods, developed since the 1970s. The principle is to identify 4–25 anatomical landmarks per vertebrae and per images. This identification time is hardly manageable in clinical practice. A semi-automated method is used: 3D standard vertebral models are positioned along with a 3D curve (identified all the way through the vertebral bodies). The silhouettes of the models of C7 and L5 vertebrae are first adjusted and the positions of the other vertebrae are interpolated and optimised. The inter- and intra-operator variabilities and the errors between the semi-automated method and the manual identification of six anatomical landmarks per vertebra are evaluated on 20 pairs of X-ray images of subjects with different spinal deformities. The identification time for the semi-automated method is 5 min. For scolitic subjects, the precision is under 2.2° and the accuracy is under 3.2° for all lateral, sagittal and axial rotations.Keywords
This publication has 59 references indexed in Scilit:
- Three-Dimensional Classification of Spinal Deformities Using Fuzzy ClusteringSpine, 2006
- Surgical Correction of Scoliosis by In Situ ContouringSpine, 2004
- Three-dimensional surface rendering reconstruction of scoliotic vertebrae using a non stereo-corresponding points techniqueEuropean Spine Journal, 2002
- Long-term three-dimensional changes of the spine after posterior spinal instrumentation and fusion in adolescent idiopathic scoliosisEuropean Spine Journal, 1999
- Curvilinear Three-Dimensional Modeling of Spinal Curves with Dual KrigingComputer Methods in Biomechanics and Biomedical Engineering, 1999
- Posterolateral lumbar fusion using facet joint fixation with biodegradable rods: A pilot studyEuropean Spine Journal, 1997
- A contouring program based on dual kriging interpolationEngineering with Computers, 1993
- Evaluation of Euler's angles with a least squares method for the study of lumbar spine motionJournal of Biomedical Engineering, 1990
- Estimation of Vertebral Rotation and the Spinal and Rib Cage Deformity in Scoliosis by Computer TomographySpine, 1981
- Spinal analysis using a three-dimensional radiographic techniqueJournal of Biomechanics, 1976