Feasibility of three-dimensional artificial intelligence algorithm integration with intracardiac echocardiography for left atrial imaging during atrial fibrillation catheter ablation
Open Access
- 21 July 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Abstract
Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52–0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.Keywords
This publication has 18 references indexed in Scilit:
- Integrated 3D intracardiac ultrasound imaging with detailed pulmonary vein delineation guided fluoroless ablation of atrial fibrillationPacing and Clinical Electrophysiology, 2021
- Outcomes and Safety of Fluoroless Catheter Ablation for Atrial FibrillationCJC Open, 2021
- Intracardiac echocardiography guided nonocclusive balloon cryothermal applications to achieve antral isolation during pulmonary vein isolationJournal of Interventional Cardiac Electrophysiology, 2020
- Artificial Intelligence and Machine Learning in Arrhythmias and Cardiac ElectrophysiologyCirculation: Arrhythmia and Electrophysiology, 2020
- Fluoroless Atrial Fibrillation Catheter AblationCardiac Electrophysiology Clinics, 2020
- Outcomes of 200 consecutive, fluoroless atrial fibrillation ablations using a new techniquePacing and Clinical Electrophysiology, 2018
- Fluoroless catheter ablation of atrial fibrillationHeart Rhythm, 2017
- Impact of catheter tip-tissue contact on three-dimensional left atrial geometries: Relationship between the external structures and anatomic distortion of 3D fast anatomical mapping and high contact force guided imagesInternational Journal of Cardiology, 2016
- Visualization of the left atrial appendage by phased-array intracardiac echocardiography from the pulmonary artery in patients with atrial fibrillationEP Europace, 2015
- Determination of left atrium volume by fast anatomical mapping and intracardiac echocardiography. The contribution of respiratory gatingJournal of Interventional Cardiac Electrophysiology, 2015