Fault-Tolerant Control for One-Phase Current Sensor Fault in Open-End Winding PMSM fed by Dual Inverter With a Common DC Bus
Author:
- 26 September 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 124-128
Abstract
This letter presents a fault-tolerant control (FTC) for a one-phase current sensor failure in the open-ended winding permanent magnet synchronous motor (PMSM) fed by the dual inverter with a common dc bus. While many FTC strategies for stator winding and inverter leg faults have been researched, an FTC for one-phase current sensor fault has not yet been proposed. Unlike a single inverter, the dual inverter with a common dc bus needs three-phase current measurement due to the flow of zero-sequence current (ZSC). A one-phase current sensor fault can result in immediate system shutdown or severe degradation in control performance. This study proposes a method for estimating the one-phase current using the currents from the other two phases. Both the FTC and the ZSC control can be implemented in the presence of a one-phase current sensor fault. Experimental results are provided to validate the proposed method.Keywords
Funding Information
- National Research Foundation of Korea (RS-2023-00277751)
- Korea University (K2311851)
This publication has 16 references indexed in Scilit:
- Simple Discontinuous Pulse-Width Modulation Scheme for the Loss Reduction of a Dual Inverter Fed an Open-End Winding Induction MotorIEEE Transactions on Energy Conversion, 2022
- Zero-Sequence Current Suppression Method for Fault-Tolerant OW-PMSM Drive With Asymmetric Zero-Sequence Voltage InjectionIEEE Transactions on Industrial Electronics, 2022
- Fault-Tolerant Control for Multiple Open-Leg Faults in Open-End Winding Permanent Magnet Synchronous Motor System Based on Winding ReconnectionIEEE Transactions on Power Electronics, 2020
- Simplified Modulation Scheme for Open-End Winding PMSM System With Common DC Bus Under Open-Phase Fault Based on Circulating Current SuppressionIEEE Transactions on Power Electronics, 2019
- Fault Detection and Identification Scheme for Dual-Inverter Fed OEWIM DriveIEEE Transactions on Industrial Electronics, 2019
- A Novel Zero-Sequence Current Elimination PWM Scheme for an Open-Winding PMSM With Common DC BusIEEE Transactions on Power Electronics, 2019
- Postfault Zero-Sequence Current Injection for Open-Circuit Diode/Switch Failure in Open-End Winding PMSM MachinesIEEE Transactions on Industrial Electronics, 2018
- Torque Ripple Suppression Method With Reduced Switching Frequency for Open-Winding PMSM Drives With Common DC BusIEEE Transactions on Industrial Electronics, 2018
- A new single-phase PLL structure based on second order generalized integrator2006
- Some diagnosis methods for voltage source inverters in variable speed drives with induction machines a survey2004