A novel thermally-actuated silicon micropump
Authors:
- X.Y. YeXYX.Y. Ye
- Z.Y. ZhouZZZ.Y. Zhou
- Y. YangYYY. Yang
- 23 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 231-234
Abstract
The thermal dynamics of a bimetallic microactuator in micropump are analyzed by using FEM. On the basis of the analysis, a novel thermally-actuated silicon micropump is developed. This micropump utilizes both bimetallic thermal actuation and thermal pneumatic actuation. The bimetallic microactuator is composed of an aluminum membrane and a silicon membrane. An air chamber is also designed to realize the thermal pneumatic actuation. A new micro check valve is developed through surface micromachining. This microvalve has a high reverse-to-forward flow resistance and a very small reverse leakage.Keywords
This publication has 3 references indexed in Scilit:
- Modeling micropumps with electrical equivalent networksJournal of Micromechanics and Microengineering, 1996
- Dynamic simulations of micropumpsJournal of Micromechanics and Microengineering, 1996
- Microflow devices and systemsJournal of Micromechanics and Microengineering, 1994