In situ Raman Analysis of Gas Formation in NiMH Batteries
Authors:
- 1 January 2005
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 59 (1) , 109-114
Abstract
In this paper Raman spectrometry is introduced in the field of sealed battery research for in situ gas-phase analysis and for long-term measurements. For this purpose, a new method was successfully applied in order to model battery behavior without interfering with operation. It is shown that oxygen, hydrogen, and nitrogen are responsible for the pressure increase that occurs during overcharging. The relative contribution of the different gases depends on the current imposed on the battery as well as the operating temperature. Reproducible and stable signals could be obtained even under severe conditions such as high pressure and elevated temperature. Oxygen and hydrogen are produced in side reactions taking place during battery operation. However, as nitrogen is unlikely to be a reacting gas inside the battery, the change in its partial pressure can be attributed to electrode expansion and a change in the electrolyte volume.Keywords
This publication has 7 references indexed in Scilit:
- Modelling of rechargeable NiMH batteriesJournal of Alloys and Compounds, 2003
- Raman microscopy as a quality control tool for electrodes of lithium-ion batteriesJournal of Power Sources, 2001
- Raman spectroscopic study on the surface oxide layer of AB5-type metal hydride electrodesElectrochimica Acta, 2001
- Advanced in situ methods for the characterization of practical electrodes in lithium-ion batteriesJournal of Power Sources, 2000
- In Situ Raman Spectroscopy on an Operating AA Zn-MnO[sub 2] Battery under High Discharge CurrentsElectrochemical and Solid-State Letters, 1999
- Hydrogen and oxygen evolution in sealed lead/acid 2 V cells. In situ gas measurement by Raman spectroscopyJournal of Power Sources, 1996
- Infrared and Raman Spectroscopy1995