ESTIMATING MECONIUM (FETAL FECES) CONCENTRATION IN HUMAN AMNIOTIC-FLUID BY NUCLEAR MAGNETIC-RESONANCE

Authors:
  • BBB BORCARD
    B BORCARD
  • EHE HILTBRAND
    E HILTBRAND
  • PMP MAGNIN
    P MAGNIN
  • GBGJ BENE
    GJ BENE
  • ABA BRIGUET
    A BRIGUET
  • JDJC DUPLAN
    JC DUPLAN
  • JDJ DELMAU
    J DELMAU
  • SGS GUIBAUD
    S GUIBAUD
  • MBM BONNET
    M BONNET
  • MDM DUMONT
    M DUMONT
  • JFJF FARA
    JF FARA

  • 1 January 1982
    • journal article
    • research article
    • Vol. 14  (3) , 189-192
    • PMID:7185052
Abstract
Measurements are reported of NMR relaxation times (T2) on H in water of isotonic NaCl solutions and of normal human amniotic fluid in which known concentrations of meconium (fetal feces) were dissolved. Magnetic fields for resonance of 23.5 .times. 103 and 0.6 oersteds were used. From the measured T2 values, reliable estimates of meconium concentrations could be obtained that might be considered estimates of fetal distress. Observed minor variation of T2 values was probably due to the mucopolysaccharides comprising 80% of the meconium weight. Advantages of this technique for possible clinical use in obstetrics include small volume of sample required (0.1 ml), lack of necessity for sample filtration or centrifugation and shortness of time required for analysis (< 30 min).