Precision and accuracy of an electrogoniometer
- 1 January 1999
- journal article
- research article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 22 (1) , 10-14
Abstract
Spinal range of motion has been studied by use of a variety of different methods. One electrogoniometer has been used as a noninvasive, reliable, and accurate method. The accuracy and precision of this device has not been sufficiently documented. To evaluate the precision and accuracy of an electrogoniometer in comparison with two manual protractors. This study investigated the precision and accuracy of an electrogoniometer (OSI CA 6000). The precision and accuracy of the electrogoniometer were determined by a series of tests against two manual protractors. Six different movement directions were tested and 4 or 5 different angles for a given movement direction were evaluated. The precision of the electrogoniometer was found to be +/- 0.1 degree for 4 different angles (10 degrees, 20 degrees, 40 degrees, and 60 degrees) in 6 different movement directions (flexion, extension, left lateral flexion, right lateral flexion, left rotation, and right rotation). The accuracy was tested by comparing both manual protractors with the electrogoniometer. Substantial disagreement for 27 of 28 datasets was found. In only one dataset was there agreement between the two manual protractors and the electrogoniometer. The mean differences were in the interval 2.0% to 11.5% between the electrogoniometer and the protractors. The electrogoniometer evaluated has a very high precision when range of motion measurements are made. However, the accuracy of the device is less than acceptable.Keywords
Funding Information
- Nordisk Institut for Kiropraktik og Klinisk Biomekanik
This publication has 7 references indexed in Scilit:
- Instantaneous Center of Rotation and Instability of the Cervical SpineSpine, 1997
- The Effect of a Soft Collar, Used as Normally Recommended or Reversed, on Three Planes of Cervical Range of MotionJournal of Orthopaedic & Sports Physical Therapy, 1996
- Motion Characteristics of the Lumbar Spine in the Normal PopulationSpine, 1995
- Age and Gender Related Normal Motion of the Cervical SpineSpine, 1992
- Functional Evaluation of the Spinal Cord by Magnetic Resonance Imaging in Patients with Rheumatoid Arthritis and Instability of Upper Cervical SpineSpine, 1989
- CT-Functional Diagnostics of the Rotatory Instability of Upper Cervical SpineSpine, 1987
- Cineroentgenography of the Normal Cervical SpineJournal of Bone and Joint Surgery, 1957