Mass separation of deuterium and helium with conventional quadrupole mass spectrometer by using varied ionization energy
Authors:
- 1 March 2016
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (3) , 035120
Abstract
Deuterium pressure in deuterium-helium mixture gas is successfully measured by a common quadrupole mass spectrometer (model: RGA200) with a resolution of ∼0.5 atomic mass unit (AMU), by using varied ionization energy together with new developed software and dedicated calibration for RGA200. The new software is developed by using MATLAB with the new functions: electron energy (EE) scanning, deuterium partial pressure measurement, and automatic data saving. RGA200 with new software is calibrated in pure deuterium and pure helium 1.0 × 10−6–5.0 × 10−2 Pa, and the relation between pressure and ion current of AMU4 under EE = 25 eV and EE = 70 eV is obtained. From the calibration result and RGA200 scanning with varied ionization energy in deuterium and helium mixture gas, both deuterium partial pressures (PD2) and helium partial pressure (PHe) could be obtained. The result shows that deuterium partial pressure could be measured if PD2 > 10−6 Pa (limited by ultimate pressure of calibration vessel), and helium pressure could be measured only if PHe/PD2 > 0.45, and the measurement error is evaluated as 15%. This method is successfully employed in EAST 2015 summer campaign to monitor deuterium outgassing/desorption during helium discharge cleaning.Keywords
Funding Information
- Japan Society for the Promotion of Science-National Research Foundation of Korea-National Science Foundation of China (11261140328)
- National Nature Science Foundation of China (11321092)
- National Nature Science Foundation of China (11405210)
This publication has 6 references indexed in Scilit:
- Threshold ionisation mass spectrometry (TIMS); a complementary quantitative technique to conventional mass resolved mass spectrometryVacuum, 2014
- Oxidative removal of tokamak codeposits using NO2 and O2Journal of Nuclear Materials, 2013
- ICRF (ion cyclotron range of frequencies) discharge cleaning with toroidal and vertical fields on EASTPlasma Physics and Controlled Fusion, 2010
- Overview of the KSTAR vacuum pumping systemFusion Engineering and Design, 2009
- Oxygen removal with D2-ICR cleanings after oxidation experiment in HT-7Fusion Engineering and Design, 2007
- Evaluation of small mass spectrometer systems for permanent gas analysisJournal of the American Society for Mass Spectrometry, 2002