Abstract
To date, no ideal heart valve prosthesis for the replacement of a diseased natural valve or for use in ventricular assist devices exists. Valves still cause thromboembolic complications originating from thrombus formations in the valve’s stagnant and recirculation zones. Optimization of valve design requires detailed flow field investigations. Usually, the regions that are more prone to thrombus formation can be estimated using a dye washout experiment. This successful experimental method was simulated using numerical methods. The proposed method was applied to three standard mechanical heart valves—Björk-Shiley, St-Jude, and Starr-Edwards valve. The dye washout was characterized by a time course of the gray value averaged over a defined region of interest. Finally, these curves were quantified by a half dye time (HDT), which characterizes the blood residence time. The HDT in the best valve, the Starr-Edwards valve, was 0.0747 s. The HDT in the worst valve, the Björk-Shiley, was 0.0942 s. The analysis of the hemodynamic valve parameters (pressure drop, velocity magnitudes and turbulence) revealed that the best valve is the St-Jude valve. The Starr-Edwards valve displayed the worst hemodynamic parameters. This study shows that the proposed numerical method of dye washout visualization can be used as an additional tool for the flow characterization.Keywords
This publication has 23 references indexed in Scilit:
- Characterization of an Artificial Valve Flow Using the Numerical Dye Washout Visualization Technique: Application to the Monoleaflet Valve With Purged FlowArtificial Organs, 2006
- Flow in Prosthetic Heart Valves: State-of-the-Art and Future DirectionsAnnals of Biomedical Engineering, 2005
- A simulated dye method for flow visualization with a computational model for blood flowJournal of Biomechanics, 2004
- Numerical Estimation of Blood Damage in Artificial OrgansArtificial Organs, 2004
- Optimal Oral Anticoagulant Therapy in Patients with Mechanical Heart ValvesNew England Journal of Medicine, 1995
- Numerical simulation of unsteady laminar flow through a tilting disk heart valve: Prediction of vortex sheddingJournal of Biomechanics, 1994
- A polygonal approximation to direct scalar volume renderingACM SIGGRAPH Computer Graphics, 1990
- Trial of Different Intensities of Anticoagulation in Patients with Prosthetic Heart ValvesNew England Journal of Medicine, 1990
- The geometry of the aortic root in health, at valve disease and after valve replacementJournal of Biomechanics, 1990
- Computer-Assisted Design of Butterfly Bileaflet Valves for the Mitral PositionScandinavian Journal of Thoracic and Cardiovascular Surgery, 1985