How Do Coil Configuration and Packing Density Influence Intra-Aneurysmal Hemodynamics?
Open Access
- 1 September 2011
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (10) , 1935-1941
Abstract
BACKGROUND AND PURPOSE: Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics. MATERIALS AND METHODS: Three 3D rotational angiography images of 3 intracranial aneurysms before and after endovascular coiling were used. For each aneurysm, a 3D representation of the vasculature was obtained after the segmentation of the images. Afterward, a virtual coiling technique was used to treat the aneurysm geometries with coil models. The aneurysms were coiled with 5 packing densities, and each was generated by using 3 coil configurations. Computational fluid dynamics analyses were carried out in both untreated and treated aneurysm geometries. Statistical tests were performed to evaluate the relative effect of coil configuration on local hemodynamics. RESULTS: The intra-aneurysmal blood flow velocity and wall shear stress were diminished as packing density increased. Aneurysmal flow velocity was reduced >50% due to the first inserted coils (packing density .01) were found in the hemodynamics due to coil configuration for high packing densities (near 30%). A damping effect was observed on the intra-aneurysmal blood flow waveform after coiling. CONCLUSIONS: Intra-aneurysmal hemodynamics are altered by coils. Coil configuration might reduce its influence on intra-aneurysmal hemodynamics as the packing density increases until an insignificant influence could be achieved for high packing densities.Keywords
This publication has 27 references indexed in Scilit:
- Critical Influence of Framing Coil Orientation on Intra-Aneurysmal and Neck Region Hemodynamics in a Sidewall Aneurysm ModelNeurosurgery, 2010
- Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of TreatmentAmerican Journal of Neuroradiology, 2010
- In Vitro Study of Near-Wall Flow in a Cerebral Aneurysm Model with and without CoilsAmerican Journal of Neuroradiology, 2010
- Quantitative Effects of Coil Packing Density on Cerebral Aneurysm Fluid Dynamics: An In Vitro Steady Flow StudyAnnals of Biomedical Engineering, 2010
- Computational Fluid Dynamics Simulations of Intracranial Aneurysms at Varying Heart Rates: A “Patient-Specific” StudyJournal of Biomechanical Engineering, 2009
- Coils in a Nutshell: A Review of Coil Physical PropertiesAmerican Journal of Neuroradiology, 2008
- The Merits of Endovascular Coil Surgery for Patients with Unruptured Intracranial AneurysmsJournal of Korean Neurosurgical Society, 2008
- Computation of Hemodynamics in the Circle of WillisStroke, 2007
- Development and validation of models for the investigation of blood clotting in idealized stenoses and cerebral aneurysmsJournal of Artificial Organs, 2005
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003