Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
Authors:
- José María HernándezJHJosé María Hernández
- Berta SoldevilaBSBerta Soldevila
- Inés VelascoIVInés Velasco
- Fernando Moreno-FloresFMFernando Moreno-Flores
- Laura FerrerLFLaura Ferrer
- Alejandra Pérez-Montes de OcaAOAlejandra Pérez-Montes de Oca
- Cecilia SantillánCSCecilia Santillán
- Carla MuñozCMCarla Muñoz
- Sílvia BallestaSBSílvia Ballesta
- Cristina CanalCCCristina Canal
- Manel Puig-DomingoMPManel Puig-Domingo
- María Luisa GranadaMGMaría Luisa Granada
Open Access
- 31 May 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (11) , 2444
Abstract
Background: Recent guidelines recommend establishing a local reference interval (RI) for thyroid function. We aimed to establish trimester-specific RIs for thyrotropin (TSH) and free thyroxine (FT4) in a cohort of healthy pregnant women in Catalonia (Spain). Methods: A prospective observational study was conducted with 332 healthy pregnant women, from the first trimester (1T) to delivery. TSH was measured using an Architect® immunoassay (Abbott) and FT4 by two immunoassays, Architect® (Abbott) and Cobas® (Roche), in the three trimesters. FT4 was also measured by liquid chromatography mass spectrometry (LC/MS/MS) in the 1T. Results: TSH (µUI/mL) increased throughout pregnancy (1T: 0.03–3.78; 2T: 0.51–3.53; 3T: 0.50–4.32; p < 0.0001) and FT4 (pmol/L) progressively decreased (Architect® 1T: 10.42–15.96; 2T: 8.37–12.74; 3T: 8.24–12.49; p < 0.0001; and Cobas®: 1T: 11.46–19.05; 2T: 9.65–14.67; 3T: 8.88–14.54; p < 0.0067). The FT4 RI during 1T determined LC/MS/MS was 8.75–18.27. Despite the 1T FT4 results measured by LC/MS/MS and with the two immunoassays being significantly correlated, the results obtained by the three methods were found to be non-interchangeable. Conclusions: We established trimester-specific RIs for TSH and for FT4 with immunoassays in our population. We also validated the 1T FT4 using LC/MS/MS to confirm the results of FT4 lower than the 2.5th percentile or higher than the 97.5th percentile.Keywords
Funding Information
- Instituto de Salud Carlos III (PI15/02192)
This publication has 27 references indexed in Scilit:
- FT4 immunoassays may display a pattern during pregnancy similar to the equilibrium dialysis ID–LC/tandem MS candidate reference measurement procedure in spite of susceptibility towards binding protein alterationsClinica Chimica Acta, 2010
- Free thyroxine reference interval in each trimester of pregnancy determined with the Roche Modular E-170 electrochemiluminescent immunoassayClinical Biochemistry, 2008
- Free Thyroid Hormones in Serum by Direct Equilibrium Dialysis and Online Solid-Phase Extraction–Liquid Chromatography/Tandem Mass SpectrometryClinical Chemistry, 2008
- Simultaneous quantification of free triiodothyronine and free thyroxine by isotope dilution tandem mass spectrometryClinical Biochemistry, 2007
- Tandem Mass Spectrometry Improves the Accuracy of Free Thyroxine Measurements During PregnancyThyroid®, 2007
- Measurement of free thyroxine in laboratory medicine – proposal of measurand definitionClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serumClinical Chemistry and Laboratory Medicine (CCLM), 2007
- The measurement of free thyroxine by isotope dilution tandem mass spectrometryClinica Chimica Acta, 2005
- Clinical Evaluation of Nine Free Thyroxine Assays: Persistent Problems in Particular PopulationsClinical Chemistry and Laboratory Medicine (CCLM), 2003
- A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part IClinical Chemistry and Laboratory Medicine (CCLM), 1983