Repeatability and agreement of a new anterior segment optical coherence tomography with standard devices in normal, keratoconus, and post-refractive eyes
Authors:
Open Access
- 26 February 2025
- journal article
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 325-334
Abstract
Purpose: To assess repeatability and agreement of Eyestar 900 (Haag-Streit, Köniz, Switzerland) with Pentacam AXL Wave system (Oculus, Wetzlar, Germany), Anterion (Heidelberg Engineering GmBH, Heidelberg, Germany), and MS-39 (CSO, Florence, Italy) in measuring anterior segment parameters. Methods: Two hundred normal eyes, 50 keratoconus (KC) eyes, and 50 post-refractive surgery eyes underwent three sequential scans on each instrument. The order of scans was randomized. Repeatability was assessed using within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC). Bland–Altman analysis was used to assess the 95% limits of agreement. Results: Eyestar 900 had comparable repeatability to Anterion and MS-39 across groups. ICC was overall >0.8. Pentacam AXL Wave had lower Sw (better repeatability) across all groups. In normal eyes, Eyestar 900 can be used interchangeably with MS-39 and Anterion ( P > 0.23). Eyestar 900 and Pentacam AXL Wave did not show agreement on any parameter, except anterior chamber depth (ACD) ( P = 0.92). Eyestar 900 in KC eyes can be used interchangeably with MS-39, except for posterior keratometry (pK) and thinnest corneal thickness (TCT) ( P < 0.001), and with Anterion, except for TCT and ACD ( P < 0.001). In post-refractive eyes, Eyestar 900 can be used interchangeably with MS-39, except for pK ( P < 0.001), and with Anterion, except for ACD ( P < 0.001). Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably in KC and post-refractive eyes. Conclusions: Newer devices such as Eyestar 900 can be used interchangeably with Anterion and MS-39 in normal eyes and partly in KC and post-refractive eyes. Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably across the various groups. However, these multifunctional hybrid tools of combined topography, AS-OCT, can be helpful in refractive clinics.Keywords
This publication has 27 references indexed in Scilit:
- Five-year follow-up of corneal morphology and corneal refractive power changes after uneventful DMEKGraefe's Archive for Clinical and Experimental Ophthalmology, 2022
- Agreement of white-to-white measurements with swept-source OCT, Scheimpflug and color LED devicesInternational Ophthalmology, 2020
- Anterior segment optical coherence tomographyProgress in Retinal and Eye Research, 2018
- Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug camerasJournal of Cataract & Refractive Surgery, 2018
- Implantable Collamer Lens Sizing Method Based on Swept-Source Anterior Segment Optical Coherence TomographyAmerican Journal of Ophthalmology, 2018
- Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCTGraefe's Archive for Clinical and Experimental Ophthalmology, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Precision (repeatability and reproducibility) studies and sample-size calculationJournal of Cataract & Refractive Surgery, 2015
- Reproducibility of Peripapillary Retinal Nerve Fiber Thickness Measurements with Stratus OCT in Glaucomatous EyesOphthalmology, 2008
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986