The effect of drill-generated noise in the contralateral healthy ear following mastoid surgery: The emphasis on hearing threshold recovery time
Open Access
- 1 January 2015
- journal article
- research article
- Published by Medknow in Noise and Health
- Vol. 17 (77) , 209-15
Abstract
In mastoid surgeries, contralateral ear noise exposure is a known, identified factor leading to high-frequency hearing loss due to the wide variety of surgical devices that may be used during the surgery. However, the hearing threshold recovery time after this trauma was uncertain. The present study aimed to assess this time. In this prospective survival analysis study, 28 consecutive patients with chronic otitis media who were undergoing tympanomastoidectomy were assessed. Standard pure-tone audiometry (PTA) and distortion-product otoacoustic emission (DPOAE) were measured in all contralateral ears before and 6 h, 24 h, 48 h, 72 h, and 96 h after the surgery. Based on the PTA postoperative hearing loss, survival rates at frequencies of 3000 Hz, 4000 Hz, 6000 Hz, and 8000 Hz were 44.4%, 36.4%, 51.7%, and 47.4%, 24 h after surgery; 11.1%, 9.1%, 10.3%, and 13.2%, 48 h after surgery; and 0%, 0%, 3.4%, and 2.6%, 72 h after surgery, respectively. Based on the PTA and DPOAE, survival rates at all frequencies were 0%, 96 h after the surgery. According to the PTA, mean hearing recovery times were 61.98 ± 26.76 h (3000 Hz), 62.73 ± 26.50 h (4000 Hz), 67.08 ± 25.90 h (6000 Hz), 70.70 ± 24.13 h (8000 Hz), and with regard to DPOAE the recovery times were 58.58 ± 28.39 h (2000 Hz), 63.32 ± 28.83 h (4000 Hz), 65.22 ± 29.13 h (6000 Hz), and 75.14 ± 22.70 h (8000 Hz), respectively. To conclude, high-frequency hearing loss usually occurs following mastoid surgeries that is mainly temporary and reversible after 72 h.Keywords
This publication has 19 references indexed in Scilit:
- Evaluation of the usefulness of a silicone tube connected to a microphone in monitoring noise levels induced by drilling during mastoidectomy and cochleostomyActa Oto-Laryngologica, 2010
- Does drill-induced noise have an impact on sensorineural hearing during craniotomy procedure?British Journal Of Neurosurgery, 2010
- Implications of Sound Levels Generated by Otologic DevicesOtolaryngology–Head and Neck Surgery, 2001
- Drill-induced hearing loss in the nonoperated earOtolaryngology–Head and Neck Surgery, 1997
- Drill‐generated sensorineural hearing loss following mastoid surgeryThe Laryngoscope, 1992
- [Cochlear damage caused by middle ear surgeries].1991
- Sensorineural high-frequency hearing loss after drill-generated acoustic trauma in tympanoplastyEuropean Archives of Oto-Rhino-Laryngology, 1989
- DOES DRILL NOISE DURING MASTOID SURGERY AFFECT THE CONTRALATERAL EAR1985
- Variables Affecting the Drill-Generated Noise Levels in Ear SurgeryActa Oto-Laryngologica, 1977
- Drill-Generated Noise Levels in ear SurgeryActa Oto-Laryngologica, 1976