Early In Vivo Experience With the Pediatric Jarvik 2000 Heart
Authors:
- 1 May 2007
- journal article
- pediatric mechanical-circulatory-support
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 53 (3) , 374-378
Abstract
The need for smaller, more efficient ventricular assist devices that can be used in a more chronic setting have led to exploration of mechanical circulatory support in the pediatric population. The pediatric Jarvik 2000 heart (child size), under development, was implanted in six juvenile sheep and studied for both acute fit and chronic performance evaluation. Daily hemodynamic measurements of cardiac output and pump output at varying pump speeds were taken. In addition, plasma free hemoglobin, lactic acid dehydrogenase, and platelet activation from blood samples were determined at baseline, after implantation, and twice a week thereafter. The measured flow through the outflow graft at increasing speeds from 10,000 rpm to 14,000 rpm with an increment of 1,000 rpm were 1.47 ± 0.43, 1.89 ± 0.52, 2.36 ± 0.61, 2.80 ± 0.73, and 3.11 ± 0.86 (L/min). The baseline plasma free hemoglobin was 11.95 ± 4.76 (mg/dL), with subsequent mean values being in vivo experience with the pediatric Jarvik 2000 heart shows that a small axial flow pump can provide partial to nearly complete circulatory support with minimal adverse effects on blood components.Keywords
This publication has 10 references indexed in Scilit:
- The National Heart, Lung, and Blood Institute Pediatric Circulatory Support ProgramCirculation, 2006
- Mechanical Circulatory AssistanceCirculation, 2002
- Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist SystemCirculation, 2002
- Mechanical circulatory support for infants and children with cardiac diseaseThe Annals of Thoracic Surgery, 2002
- Mortality Associated With Congenital Heart Defects in the United StatesCirculation, 2001
- Indications and patient selection for mechanical ventricular assistanceThe Annals of Thoracic Surgery, 2001
- Quantification of Platelet Activation Status by Analyzing P-Selectin ExpressionBiochemical and Biophysical Research Communications, 2000
- Mechanical circulatory support in children with cardiac diseaseThe Journal of Thoracic and Cardiovascular Surgery, 1999
- Species Differences in Erythrocyte Mechanical FragilityASAIO Journal, 1998
- Plasma Hemoglobin Measurement Techniques for the In Vitro Evaluation of Blood Damage Caused by Medical DevicesArtificial Organs, 1997