Performance of Unmodified Mechanical Ventilators With 2% Hydrogen Gas Mixtures
Authors:
- 2 April 2025
- journal article
- Published by SAGE Publications in Respiratory Care
- Vol. 70 (4) , 377-383
Abstract
Background: Molecular hydrogen (H 2 ) is a breathable gas that has been shown to have anti-oxidative, anti-inflammatory, and anti-apoptotic properties that may positively impact ischemia-reperfusion injury. The provision of 2% H 2 through unmodified mechanical ventilators may facilitate the clinical translation of H 2 as a therapeutic in critical illness. The effect of 2% H 2 on ventilator performance is unknown. Methods: Unmodified Maquet Servo-i, Maquet Servo-u, Dräger Evita Infinity V500, and Dräger Evita Babylog VN500 ventilators from clinical stock were tested in an experimental closed system using certified, premixed air and O 2 containing 2% H 2 gas. Wall air and O 2 supply were used as control. Ventilator settings were varied across the spectrum of neonatal to adult settings. End points included (1) difference between set and delivered tidal volume (V T ) (Douglas method), (2) difference between set versus delivered O 2 concentration, (3) delivered H 2 concentration (gas chromatography), and (4) ventilator pre-use check malfunction. Correlation between set and measured end points were quantified by linear regression analysis and bias by Bland-Altman analysis. Results: During H 2 administration, the average bias in measured versus set V T was within ± 10% for all ventilators except for the Babylog VN500, which exhibited an average bias of −89.2% (95% CI −107.0 to −71.3). The average bias in measured F IO 2 was within ± 10% of set for all ventilators. Except for the Babylog VN500, all ventilators passed the pre-use check. Conclusions: Unmodified Servo-i, Servo-u, and Evita V500 ventilators deliver 2% H 2 mixtures with acceptable accuracy in V T and F IO 2 . The Babylog VN500, which uses hot-wire anometry and a higher set operating temperature, exhibits unacceptably inaccurate delivery of V T with H 2 mixtures.Keywords
This publication has 18 references indexed in Scilit:
- Safety of Prolonged Inhalation of Hydrogen Gas in Air in Healthy AdultsCritical Care Explorations, 2021
- Experimental study of the lower flammability limits of H2/O2/CO2 mixtureInternational Journal of Hydrogen Energy, 2020
- Perioperatively Inhaled Hydrogen Gas Diminishes Neurologic Injury Following Experimental Circulatory Arrest in SwineJACC: Basic To Translational Science, 2019
- Hydrogen Inhalation is Superior to Mild Hypothermia for Improving Neurological Outcome and Survival in a Cardiac Arrest Model of Spontaneously Hypertensive RatShock, 2018
- Hydrogen Gas Inhalation Treatment in Acute Cerebral Infarction: A Randomized Controlled Clinical Study on Safety and NeuroprotectionJournal of Stroke and Cerebrovascular Diseases, 2017
- Hydrogen Inhalation is Superior to Mild Hypothermia in Improving Cardiac Function and Neurological Outcome in an Asphyxial Cardiac Arrest Model of RatsShock, 2016
- Effect of Hydrogen Gas on the Survival Rate of Mice Following Global Cerebral IschemiaShock, 2012
- Inhaled Hydrogen Gas Therapy for Prevention of Lung Transplant-Induced Ischemia/Reperfusion Injury in RatsTransplantation, 2010
- Hydrogen Inhalation Ameliorates Oxidative Stress in Transplantation Induced Intestinal Graft InjuryAmerican Journal of Transplantation, 2008
- Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicalsNature Medicine, 2007