To study the long-term results of implantation of the 3M diffractive multifocal intraocular lens (IOL). Eye Department, ASA, Arendal, Norway. The study comprised 97 eyes in 72 patients. Follow-up was 8 years. Distance and near visual acuities, refractive results, contrast sensitivity, IOL centration, and neodymium:YAG (Nd:YAG) capsulotomies to treat posterior capsule opacification were evaluated. All patients without ocular pathology achieved a best corrected visual acuity (BCVA) of 0.5 or better (i.e., 98.7% had a BCVA of 1.0 or better). Without correction, 73.8% of eyes had a Jaeger acuity of J3 or better and with distance correction, 92.1%. Emmetropia or within +/-0.25 diopter (D) of it was achieved in 58.8% of eyes. An astigmatic shift of 0.827 D cylinder correction was induced. This shift was mainly against the rule (0.717 D). Contrast sensitivity was reduced with spatial frequencies of 6 to 18 cycles per degree. No need for spectacles was reported by 54.2% of patients and by 68.0% of those with bilateral implantation. For near tasks, 63.9% of patients never used spectacles. The IOLs were well centered or minimally decentered in 99.0% of eyes. Posterior capsule opacification was treated by Nd:YAG laser capsulotomy in 55.7% of eyes, with a mean time between surgery and treatment of 34.0 months +/- 23.2 (SD). This long-term study proved the 3M diffractive IOL to be safe and effective despite some reduction in contrast sensitivity at higher spatial frequencies. More than half the patients never wore spectacles; 2 of 3 patients with IOLs in both eyes never wore spectacles. Proper patient selection is crucial.Keywords
This publication has 25 references indexed in Scilit:
- Contrast sensitivity, glare, and visual function: Diffractive multifocal versus bilateral monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 1995
- Evaluating surgically induced astigmatismJournal of Cataract & Refractive Surgery, 1994
- Contrast sensitivity and glare in patients with a diffractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 1993
- Beurteilung der Abbildungsqualität bi- und multifokaler Intraokularlinsen durch ein neues optisches SystemKlinische Monatsblätter für Augenheilkunde, 1992
- Intraocular Lens Power Calculations for Multifocal Intraocular LensesAmerican Journal of Ophthalmology, 1992
- Contrast Sensitivity and Reading Through Multifocal Intraocular LensesArchives of Ophthalmology (1950), 1992
- Multifocal versus monofocal intraocular lenses Visual and refractive comparisonsJournal of Cataract & Refractive Surgery, 1992
- Contrast sensitivity as a function of focus in patients with the diffractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 1990
- Multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 1990
- Optical performance of multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 1990