Evaluating corrections for Eddy‐currents and other EPI distortions in diffusion MRI: methodology and a dataset for benchmarking
Open Access
- 5 November 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2774-2787
Abstract
Purpose: To propose a methodology for assessment of algorithms that correct distortions due to motion, eddy‐currents, and echo planar imaging in diffusion weighted images (DWIs). Methods: The proposed method evaluates correction performance by measuring variability across datasets of the same object acquired with images having distortions in different directions, thereby overcoming the unavailability of ground‐truth, undistorted DWIs. A comprehensive diffusion MRI dataset, collected using a suitable experimental design, is made available to the scientific community, consisting of three DWI shells (Bmax = 5000 s/mm2), 30 gradient directions, a replicate set of antipodal gradient directions, four phase‐encoding directions, and three different head orientations. The proposed methodology was tested using the TORTOISE diffusion MRI processing pipeline. Results: The median variability of the original distorted data was 123% higher for DWIs, 100–168% higher for tensor‐derived metrics and 28–111% higher for MAPMRI metrics, than in the corrected versions. EPI distortions induced substantial variability, nearly comparable to the contribution of eddy‐current distortions. Conclusions: The dataset and the evaluation strategy proposed herein enable quantitative comparison of different methods for correction of distortions due to motion, eddy‐currents, and other EPI distortions, and can be useful in benchmarking newly developed algorithms.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (W81XWH‐13‐2‐0019)
This publication has 37 references indexed in Scilit:
- Multi-site genetic analysis of diffusion images and voxelwise heritability analysis: A pilot project of the ENIGMA–DTI working groupNeuroImage, 2013
- Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography resultsNeuroImage, 2012
- A framework for the analysis of phantom data in multicenter diffusion tensor imaging studiesHuman Brain Mapping, 2012
- Common data elements in radiologic imaging of traumatic brain injuryJournal of Magnetic Resonance Imaging, 2010
- Correcting eddy current and motion effects by affine whole‐brain registrations: Evaluation of three‐dimensional distortions and comparison with slicewise correctionMagnetic Resonance in Medicine, 2010
- Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar ImagingNeuroImage, 2010
- Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolutionNeuroImage, 2004
- Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imagingMagnetic Resonance in Medicine, 2002
- Characterization of anisotropy in high angular resolution diffusion‐weighted MRIMagnetic Resonance in Medicine, 2002
- Unwarping of unidirectionally distorted EPI imagesIEEE Transactions on Medical Imaging, 2000