Abstract
This paper presents a seismic evaluation of the University of Alaska Anchorage (UAA) Engineering Building (UAAEB). The building was designed and constructed in 1981 to the 1979 Uniform Building Code using moment resisting space frames. The evaluation was performed using current design practice following the 2000 IBC and FEMA 273 requirements. A dynamic time history analysis was performed using a synthesized earthquake record based on the Mw 9.2 "Great Alaska Earthquake of 1964". Strong shaking exceeded 90 seconds, with felt motion lasting for over 4 minutes. Anchorage suffered significant damage due to the event. The peak horizontal ground acceleration on bedrock was estimated at 0.218g. Extensive development has occurred in this area of Anchorage since 1964, including the UAA Campus, and nearby, the Alaska Native Medical Center, and Providence Alaska Medical Center. Geotectnical investigations have identified the UAA Campus as highly susceptible to amplified seismic ground motions on the order of 2.5 or higher. A thorough investigation of the building was conducted using the 2000 Edition of International Building Code (ICC 2000); FEMA-273 (FEMA 1997 a). "NEHRP Guidelines for the Seismic Rehabilitation of Buildings"; and FEMA 310, "Handbook for the Seismic Evaluation of Buildings — A Pre-Standard." Pushover analysis studies identified elements of the structure critical to reducing damage. These critical elements were identified for seismic retrofit.