Clinical factors influencing implant positioning by guided surgery using a nonmetal sleeve template in the partially edentulous ridge: Multiple regression analysis of a prospective cohort
- 9 September 2020
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 31 (12) , 1187-1198
Abstract
Objective: To determine the positional accuracy of implants placed with a three‐dimensionally printed template having nonmetal sleeves and to determine the contributing factors to observed deviations.Materials and Methods: One hundred and eighty‐seven implants placed in 72 patients were analyzed. Presurgical intraoral scans and cone‐beam computed tomography images obtained before and after surgery were superimposed, and vertical, angular, platform, and apex deviations were measured between the virtually planned and actually placed positions. A multiple linear regression model was designed for identifying the contributing factors. Statistical significance was set at p < .05, with Bonferroni correction if necessary (p < .0167).Results: A total of 187 implants demonstrated deviations of 0.65 [0.56, 0.75] mm (mean [95% confidence interval]) vertically, 3.59° [3.30°, 3.89°] angularly, 1.16 [1.04, 1.28] mm at platform, and 1.50 [1.36, 1.65] mm at apex. Implants placed in the mandible showed larger angular, platform, and apex deviations compared with those in the maxilla (p = .049, p = .014 and p = .003, respectively). Implants placed at the third or fourth nearest sites from the most‐distal tooth had larger deviations than those placed at the first or second nearest sites, in vertical, platform, and apical aspects (p = .015, p = .011 andp = .018, respectively). This was only applicable to free‐ending‐supported templates (p < .0167), and anchor pin‐supported free‐ending templates (p < .0167).Conclusion: Using a three‐dimensionally printed surgical template with a nonmetal sleeve in the partial edentulous ridge resulted in larger deviations in implants placed in the mandible or distal free‐end third or fourth nearest site.Keywords
Funding Information
- National Research Foundation of Korea (HI17C1901)
This publication has 38 references indexed in Scilit:
- The intrinsic error of a stereolithographic surgical template in implant guided surgeryInternational Journal of Oral and Maxillofacial Surgery, 2013
- Computer‐guided implant therapy and soft‐ and hard‐tissue aspects. The Third EAO Consensus Conference 2012Clinical Oral Implants Research, 2012
- Accuracy of computer‐aided implant placementClinical Oral Implants Research, 2012
- Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agentsMedicina Oral Patología Oral y Cirugia Bucal, 2012
- Digital protocol for reference-based guided surgery and immediate loading: a prospective clinical studyInternational Journal of Oral and Maxillofacial Surgery, 2011
- Factors influencing transfer accuracy of cone beam CT‐derived template‐based implant placementClinical Oral Implants Research, 2011
- Root Contact during Drilling for Microimplant PlacementThe Angle Orthodontist, 2010
- A systematic review on the accuracy and the clinical outcome of computer‐guided template‐based implant dentistryClinical Oral Implants Research, 2009
- Reliability of Implant Placement With Stereolithographic Surgical Guides Generated From Computed Tomography: Clinical Data From 94 ImplantsJournal of Periodontology, 2008
- Clinical Application of Stereolithographic Surgical Guides for Implant Placement: Preliminary ResultsJournal of Periodontology, 2005