Natural Ventilation with Heat Recovery: A Biomimetic Concept
Open Access
Abstract
In temperate countries, heat recovery is often desirable through mechanical ventilation with heat recovery (MVHR). Drawbacks of MVHR include use of electric power and complex ducting, while alternative passive heat recovery systems in the form of roof or chimney-based solutions are limited to low rise buildings. This paper describes a biomimetic concept for natural ventilation with heat recovery (NVHR). The NVHR system mimics the process of water/mineral extraction from urine in the Loop of Henle (part of human kidney). Simulations on a facade-integrated Chamber successfully imitated the geometry and behaviour of the Loop of Henle (LoH). Using a space measuring 12 m2 in area and assuming two heat densities of 18.75 W/m2 (single occupancy) or 30 W/m2 (double occupancy), the maximum indoor temperatures achievable are up to 19.3 °C and 22.3 °C respectively. These come with mean relative ventilation rates of 0.92 air changes per hour (ACH) or 10.7 L·s−1 and 0.92 ACH (11.55 L·s−1), respectively, for the month of January. With active heating and single occupant, the LoH Chamber consumes between 65.7% and 72.1% of the annual heating energy required by a similar naturally ventilated space without heat recovery. The LoH Chamber could operate as stand-alone indoor cabinet, benefitting refurbishment of buildings and evading constraints of complicated ducting, external aesthetic or building age.Keywords
This publication has 19 references indexed in Scilit:
- Monitoring the performance of low energy dwellings: Two UK case studiesEnergy and Buildings, 2013
- The monitored performance of the first new London dwelling certified to the Passive House standardEnergy and Buildings, 2013
- Review on heat recovery technologies for building applicationsRenewable and Sustainable Energy Reviews, 2012
- Analytical and experimental analysis of a low-pressure heat exchanger suitable for passive ventilationEnergy and Buildings, 2011
- A comparison of the energy and carbon implications of new systems of energy provision in new build housing in the UKEnergy Policy, 2011
- Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildingsEnergy Conversion and Management, 2011
- Comparative study between a ceramic evaporative cooler (CEC) and an air-source heat pump applied to a dwelling in SpainEnergy and Buildings, 2010
- The cooling potential of earth–air heat exchangers for domestic buildings in a desert climateBuilding and Environment, 2006
- Determination of effectiveness of heat-pipe heat recovery for naturally-ventilated buildingsApplied Thermal Engineering, 1998
- Air-To-Air Heat-Exchangers for HousesAnnual Review of Energy, 1988