Hemodynamic Optimization by Invasive Ramp Test in Patients Supported With HeartMate 3 Left Ventricular Assist Device
Authors:
- 19 February 2024
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (8) , 641-650
Abstract
In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) p = 0.03 for both), predominantly due to lower cardiac readmission-free rates (p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.Keywords
This publication has 28 references indexed in Scilit:
- The Hemodynamic Effects of Aortic Regurgitation in Patients Supported by a HeartMate 3 Left Ventricular Assist DeviceJournal of Cardiac Failure, 2023
- Hemodynamic Aberrancies in Left Ventricular Assist Device–Associated Heart Failure SyndromesJournal of Cardiac Failure, 2022
- Five-Year Outcomes in Patients With Fully Magnetically Levitated vs Axial-Flow Left Ventricular Assist Devices in the MOMENTUM 3 Randomized TrialJAMA, 2022
- Hemodynamic Optimization Of Left Ventricular Assist Devices During Right Heart Catheterization Ramp StudiesJournal of Cardiac Failure, 2022
- Pre-operative atrial fibrillation and early right ventricular failure after left ventricular assist device implantation: a systematic review and meta-analysisAmerican Heart Journal, 2021
- Right Ventricular Pressure–Volume Analysis During Left Ventricular Assist Device Speed Optimization Studies: Insights Into Interventricular Interactions and Right Ventricular FailureJournal of Cardiac Failure, 2021
- Association of Ambulatory Hemodynamic Monitoring of Heart Failure With Clinical Outcomes in a Concurrent Matched Cohort AnalysisJAMA Cardiology, 2019
- Optimal Haemodynamics During Left Ventricular Assist Device Support are Associated With Reduced Haemocompatibility-Related Adverse EventsEuropean Journal of Heart Failure, 2018
- Right Heart Dysfunction in Heart Failure With Preserved Ejection Fraction: The Impact of Atrial FibrillationJournal of Cardiac Failure, 2018
- Right Heart Failure After Left Ventricular Assist Device Implantation in Patients With Chronic Congestive Heart FailureThe Journal of Heart and Lung Transplantation, 2006