Novel use of ultrasound to examine regional blood flow in the mouse kidney
- 1 July 2009
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 297 (1) , F228-F235
Abstract
Conventional methods used for measuring regional renal blood flow, such as laser-Doppler flowmetry, are highly invasive, and each measurement is restricted to a discrete location. The aim of this study was to determine whether ultrasound imaging in conjunction with enhanced contrast agent (microbubbles; Vevo MicroMarker, VisualSonics) could provide a viable noninvasive alternative. This was achieved by determining changes in renal cortical and medullary rate of perfusion in response to a bolus injection of endothelin-1 (ET-1; 0.6, 1.0, or 2.0 nmol/kg) and comparing these responses to those observed in separate groups of mice with conventional laser-Doppler methods. Intravenous infusion of ET-1 in anesthetized male C57bl/6 mice resulted in a dose-dependent increase in mean arterial pressure and a dose-dependent decrease in total renal blood flow as measured by pulse-wave Doppler. ET-1 infusion resulted in a dose-dependent decrease in regional kidney perfusion as measured by both ultrasound with enhanced contrast agent and laser-Doppler measurements, verifying the use of ultrasound to measure regional kidney perfusion. Noted limitations of ultrasound imaging compared with laser-Doppler flowmetry included a lower degree of sensitivity to changes in tissue perfusion and the inability to assess rapid or transient changes in tissue perfusion. In conclusion, ultrasound represents an effective and noninvasive method for the measurement of relatively short-term, steady-state changes in regional blood flow in the mouse kidney.Keywords
This publication has 31 references indexed in Scilit:
- Contribution of Endothelin A Receptors in Endothelin 1–Dependent Natriuresis in Female RatsHypertension, 2009
- Effect of chronic IL-6 infusion on acute pressor responses to vasoconstrictors in miceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- CONTRIBUTION OF PROSTANOID TP RECEPTORS TO THE PRESSOR AND INTRARENAL HAEMODYNAMIC RESPONSE TO ENDOTHELINClinical and Experimental Pharmacology and Physiology, 2006
- High-frequency ultrasound detection and follow-up of Wilms’ tumor in the mouseUltrasound in Medicine & Biology, 2006
- Cardiovascular molecular imagingSeminars in Nuclear Medicine, 2005
- An efficient gene transfer method mediated by ultrasound and microbubbles into the kidneyThe Journal of Gene Medicine, 2004
- Comparing Dynamic Parameters of Tumor Vascularization in Nude Mice Revealed by Magnetic Resonance Imaging and Contrast-Enhanced Intermittent Power Doppler SonographyInvestigative Radiology, 2003
- Functional Role of ET B Receptors in the Renal MedullaHypertension, 2003
- The development of x-ray imaging to study renal functionKidney International, 1999
- Renal Intramedullary Infusion of l -Arginine Prevents Reduction of Medullary Blood Flow and Hypertension in Dahl Salt-Sensitive RatsHypertension, 1999