Cost-Effective and Rapid Detection of Tetrodotoxin Using Indium Tin Oxide Electrodes via In Vitro Electrophysiology and Electrochemistry
Open Access
Abstract
The real-time, cost-effective detection of marine toxins like tetrodotoxin (TTX) remains a significant challenge for the scientific community. Traditional methods, including cell-based assays (CBAs), high-performance liquid chromatography (HPLC), and automated patch clamp (APC), are time-consuming, requiring expensive lab-based equipment and highly trained personnel. Enzyme-linked immunosorbent assays (ELISAs), lateral flow assays (LFAs), and immunosensors may not be suitable for toxin analogues. Thus, a simplified approach has been developed in this study, which involves the electrophysiological and electrochemical interrogation of N2a cells grown on ITO-coated glass electrodes by measuring extracellular field potentials (EFP) in conjunction with whole-cell patch clamp recordings and electrochemical impedance spectroscopy (EIS) measurements both before and after incubation with TTX. The ITO substrate proved biocompatible and non-toxic for N2a cells. TTX exposure caused 102% inhibition in EFP values at 300 nM, confirmed by sodium current inhibition of 93% at 300 nM and 22% at 1 nM in patch clamp studies (IC50 = 6.7 nM). EIS measurements indicated concentration-dependent impedance changes in the range of 6–300 nM. This research aims to provide a proof-of-concept for integration of electrophysiological and electrochemical approaches to simplify toxin detection systems.Keywords
Funding Information
- Marie Skłodowska-Curie (945413)
This publication has 51 references indexed in Scilit:
- Toward development of dual optical and electrical cell‐based biosensor: An investigation on electrode geometry and transparent conductive material functionElectroanalysis, 2023
- A biophotoelectrode based on boronic acid-modified Chlorella vulgaris cells integrated within a redox polymerBioelectrochemistry, 2022
- A patterned polystyrene-based microelectrode array for in vitro neuronal recordingsBiomedical Microdevices, 2018
- Immunosensor array platforms based on self-assembled dithiols for the electrochemical detection of tetrodotoxins in puffer fishAnalytica Chimica Acta, 2017
- Secretory function of adrenal chromaffin cells cultured on polypyrrole filmsBiomaterials, 1996
- “Wiring” of glucose oxidase within a hydrogel made with polyvinyl imidazole complexed with [(Os-4,4′-dimethoxy-2,2′-bipyridine)Cl]+/2+1Journal of Electroanalytical Chemistry, 1995
- Culture of mammalian cells on polypyrrole-coated ITO as a biocompatible electrodeSynthetic Metals, 1995
- A numerical ac-impedance model used for the analysis of a polyvinylferrocene coated electrodeJournal of Electroanalytical Chemistry, 1994
- A tissue culture assay for tetrodotoxin, saxitoxin and related toxinsToxicon, 1988
- Tetradotoxin-sensitive and tetrodotoxin-resistant Na+ channels differ in their sensitivity to Cd2+ and Zn2+European Journal of Pharmacology, 1986