Pressure Drop Measurements on the Shell Side of a Cylindrical Shell-and-Tube Heat Exchanger
Authors:
- 1 January 1994
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 15 (3) , 42-56
Abstract
Representatkie pressure distributions from an extensive survey of the shell-side pressure field within the tube bundle of an E-type segmented-baffle shell-and-tube heat exchanger are presented. Reynolds numbers based on minimum intertubc flow area were varied within the range 270-2,200. Strategically placed tubes forming part of the bundle were fitted with pressure tappings and were used to measure (1) axial distributions of cross-flow pressure drop, symmetric about the pass partition lane and in the central vertical plane of the bundle, and also at the edge of the bundle near the bypass lane; (2) flow pressure drops between adjacent baffle compartments; and (3) circumferential pressure distributions on selected tubes in the center and at the periphery of the bundle. Comparison of the results with those obtained in a previous study with no pass partition lane reveal the effect of the removal of the central row of tubes on the shell-side flow distribution.Keywords
This publication has 3 references indexed in Scilit:
- Flow distribution on the shellside of a cylindrical shell and tube heat exchangerInternational Journal of Heat and Fluid Flow, 1993
- THE PREDICTION OF SHELLSIDE FLOW DISTRIBUTION AND PRESSURE DROP IN A SHELL AND TUBE HEAT EXCHANGER1984
- Investigations on the flow through a staggered tube bundle at Reynolds numbers up toRe=107Wärme- und Stoffübertragung, 1969