Thermal incompatibility analysis of metal-ceramic systems based on flexural displacement data
Authors:
- 15 September 1998
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 41 (4) , 614-623
Abstract
The feasibility of simple tests or analytical methods for prediction of residual stress states in metal–ceramic (MC) prostheses has not been demonstrated. Bimaterial metal–ceramic strips have been proposed to provide sensitive measures of transient and residual stress states through the measurement of midpoint deflection after cooling from the ceramic sintering temperature. The objective of this study was to apply the elastic–viscoelastic analogy to calculate transient and residual midpoint deflections in MC bimaterial strips and to compare these values with deflections measured with a beam‐bending viscometer (BBV). Calculations and measurements were made for five MC systems that were found from a clinical study to be “thermally compatible” and from two that were selected as “thermally incompatible” systems. Metal strips, 64 mm in length, 3 mm wide, and either 0.5 mm, 1.0 mm, or 2.0 mm in thickness, were veneered with four 0.25‐mm thick layers of opaque porcelain. Midpoint deflection of the MC strips (ceramic oriented in the posterior position) was measured during cooling from an initial temperature of 700°C. In general, the directions of the measured residual deflections did not agree with the “textbook” convention that negative deflections are associated with positive thermal contraction mismatch (αM − αc > 0) regardless of metal thickness. For a metal thickness of 0.5 mm, the residual midpoint deflection for all thermal contraction mismatch cases, except one, was positive (upward deflection) whereas the residual midpoint deflections were all negative when the metal thickness was increased to 1 or 2 mm, independent of the thermal contraction mismatch. The best agreement between calculated and measured values of residual midpoint deflection (+16 μm vs. +14 ± 2.3 μm, respectively) was obtained for MC bimaterial strips with a Ni‐Cr alloy (0.5 mm thick) while the largest difference (+346 μm vs. +61 ± 43.8 μm) was obtained for MC bimaterial strips with a Au‐Pd alloy (0.5 mm thick). In all but one case, changes in deflection direction as a function of metal thickness were correctly predicted by the viscoelastic analysis. The results of this study indicate that a viscoelastic model is useful for estimating thermal compatibility conditions of MC systems. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 614–623, 1998.Keywords
This publication has 16 references indexed in Scilit:
- Influence of framework design, contraction mismatch, and thermal history on porcelain checking in fixed partial denturesDental Materials, 1989
- Delayed Crack Development in Porcelain Due to Incompatibility StressJournal of Dental Research, 1988
- Use of a Bimaterial Strip to Predict Expansion CompatibilityJournal of Dental Research, 1987
- Thermal Stress Failure of Porcelain Bonded to a Palladium-Silver AlloyJournal of Dental Research, 1985
- Measurement of Softening Temperatures in Dental Bake-on PorcelainsJournal of Dental Research, 1982
- Stress and Structural Relaxation in Tempering GlassJournal of the American Ceramic Society, 1978
- Stress and Structural Relaxation in Na 2 O‐CaO‐SiO 2 GlassJournal of the American Ceramic Society, 1974
- Shear Stress Measurements at a Dental Porcelain-Gold Bond InterfaceJournal of Dental Research, 1972
- RELATION BETWEEN INELASTIC DEFORMABILITY AND THERMAL EXPANSION OF GLASS IN ITS ANNEALING RANGE*Journal of the American Ceramic Society, 1946
- Analysis of Bi-Metal ThermostatsJournal of the Optical Society of America, 1925