Flow Visualization in a Model of a Bifurcated Stent-Graft
Authors:
- 1 August 2005
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 12 (4) , 435-445
Abstract
Purpose: To use an in vitro flow model to investigate the flow patterns in a bifurcated stent-graft for abdominal aortic aneurysm (AAA) repair. Methods: Experiments were performed in an in vitro test rig incorporating a simplified non-planar model of an AAA. A two-component bifurcated device consisting of a stent structure and transparent polyurethane “graft” was deployed in the AAA model. Using a blood analogue fluid, a pulsatile blood flow waveform simulating resting flow condition was produced by means of a piston pump system. Flow patterns in the lateral and anteroposterior planes of the stent-graft were recorded and analyzed using flow visualization techniques. Results: The flow patterns within the stent-graft were complex and influenced by the geometry of the stent-graft itself, as well as that of the aortic neck and iliac vessels. Regions of flow separation, low velocity and stagnation, and slow oscillatory flow near the walls were seen in the main body of the stent-graft. Constriction at the stump in the contralateral limb resulted in flow disturbances and flow separation. Kinking at the junctions of stent segments and folding of the graft compounded these complex flow structures. Conclusions: The flow structures within stent-grafts are complex, with features that may predispose to thrombus formation. Arterial geometry, including aortic neck angulation and iliac vessel tortuosity, and the design of the stent-graft are factors that influence hemodynamics and may impact the performance of aortic stent-grafts.Keywords
This publication has 27 references indexed in Scilit:
- Abdominal aortic hemodynamic conditions in healthy subjects aged 50–70 at rest and during lower limb exercise: in vivo quantification using MRIAtherosclerosis, 2003
- Endovascular repair of abdominal aortic aneurysms: Device-specific outcomeJournal of Vascular Surgery, 2003
- Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate-term follow-up results of a European collaborative registry (EUROSTAR)British Journal of Surgery, 2000
- Mid-term Results of Endovascular Versus Open Repair for Abdominal Aortic Aneurysm in Patients Anatomically Suitable for Endovascular RepairEuropean Journal of Vascular and Endovascular Surgery, 2000
- Influence of Stent Length and Heparin Coating on Platelet ActivationThrombosis Research, 1999
- Flow instabilities induced by coronary artery stents: Assessment with an in vitro pulse duplicatorJournal of Biomechanics, 1995
- Influence of Abdominal Aortic Curvature and Resting Versus Exercise Conditions on Velocity Fields in the Normal Abdominal Aortic BifurcationJournal of Biomechanical Engineering, 1994
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Resting ConditionsJournal of Biomechanical Engineering, 1994
- Chapter 2 Fluid dynamic and hemorheologic considerationsCardiovascular Pathology, 1993
- Arterial geometry affects hemodynamics *1A potential risk factor for atherosclerosisAtherosclerosis, 1983