Converting FENO by different flows to standard flow FENO
Open Access
- 6 May 2019
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 39 (5) , 315-321
Abstract
In clinical practice, assessment of expiratory nitric oxide (FENO) may reveal eosinophilic airway inflammation in asthmatic and other pulmonary diseases. Currently, measuring of FENO is standardized to exhaled flow level of 50 ml s−1, since the expiratory flow rate affects the FENO results. To enable the comparison of FENO measured with different expiratory flows, we firstly aimed to establish a conversion model to estimate FENO at the standard flow level, and secondly, validate it in five external populations. FENO measurements were obtained from 30 volunteers (mixed adult population) at the following multiple expiratory flow rates: 50, 30, 100 and 300 ml s−1, after different mouthwash settings, and a conversion model was developed. We tested the conversion model in five populations: healthy adults, healthy children, and patients with COPD, asthma and alveolitis. FENO conversions in the mixed adult population, in healthy adults and in children, showed the lowest deviation between estimated from 100 ml s−1 and measured FENO at 50 mL s−1: −0·28 ppb, −0·44 ppb and 0·27 ppb, respectively. In patients with COPD, asthma and alveolitis, the deviation was −1·16 ppb, −1·68 ppb and 1·47 ppb, respectively. We proposed a valid model to convert FENO in healthy or mixed populations, as well as in subjects with obstructive pulmonary diseases and found it suitable for converting FENO measured with different expiratory flows to the standard flow in large epidemiological data, but not on individual level. In conclusion, a model to convert FENO from different flows to the standard flow was established and validated.Keywords
This publication has 20 references indexed in Scilit:
- Influence of mouthwashes on extended exhaled nitric oxide (FENO) analysisScandinavian Journal of Clinical and Laboratory Investigation, 2018
- Reduction of FENO by tap water and carbonated water mouthwashes: magnitude and time courseScandinavian Journal of Clinical and Laboratory Investigation, 2018
- A European Respiratory Society technical standard: exhaled biomarkers in lung diseaseEuropean Respiratory Journal, 2017
- Statistical methods for assessing agreement between two methods of clinical measurementInternational Journal of Nursing Studies, 2010
- ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005American Journal of Respiratory and Critical Care Medicine, 2005
- Short-term variability of exhaled nitric oxide in young male patients with mild asthma and in healthy subjectsRespiratory Medicine, 2002
- Exhaled Markers of Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Exhaled nitric oxide partitioned into alveolar, lower airways and nasal contributionsRespiratory Medicine, 2000
- Exhaled and nasal nitric oxide measurements: recommendations. The European Respiratory Society Task ForceEuropean Respiratory Journal, 1997
- Nitric oxide from the human respiratory tract efficiently quantified by standardized single breath measurementsActa Physiologica Scandinavica, 1997