Reproducibility of Cardiac Multifrequency MR Elastography in Assessing Left Ventricular Stiffness and Viscosity
Open Access
- 25 October 2024
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (5) , 2146-2154
Abstract
Background: Cardiac magnetic resonance elastography (MRE) shows promise in assessing the mechanofunctional properties of the heart but faces clinical challenges, mainly synchronization with cardiac cycle, breathing, and external harmonic stimulation.Purpose: To determine the reproducibility of in vivo cardiac multifrequency MRE (MMRE) for assessing diastolic left ventricular (LV) stiffness and viscosity.Study Type: Prospective.Subjects: This single‐center study included a total of 28 participants (mean age, 56.6 ± 23.0 years; 16 male) consisting of randomly selected healthy participants (mean age, 44.6 ± 20.1 years; 9 male) and patients with aortic stenosis (mean age, 78.3 ± 3.8 years; 7 male).Field Strength/Sequence: 3 T, 3D multifrequency MRE with a single‐shot spin‐echo planar imaging sequence.Assessment: Each participant underwent two cardiac MMRE examinations on the same day. Full 3D wave fields were acquired in diastole at frequencies of 80, 90, and 100 Hz during a total of three breath‐holds. Shear wave speed (SWS) and penetration rate (PR) were reconstructed as a surrogate for tissue stiffness and inverse viscous loss. Epicardial and endocardial ROIs were manually drawn by two independent readers to segment the LV myocardium.Statistical Tests: Shapiro–Wilk test, Bland–Altman analysis and intraclass correlation coefficient (ICC). P‐value <0.05 were considered statistically significant.Results: Bland–Altman analyses and intraclass correlation coefficients (ICC = 0.96 for myocardial stiffness and ICC = 0.93 for viscosity) indicated near‐perfect test–retest repeatability among examinations on the same day. The mean SWS for scan and re‐scan diastolic LV myocardium were 2.42 ± 0.24 m/s and 2.39 ± 0.23 m/s; the mean PR were 1.24 ± 0.17 m/s and 1.22 ± 0.14 m/s. Inter‐reader variability showed good to excellent agreement for myocardial stiffness (ICC = 0.92) and viscosity (ICC = 0.85).Data Conclusion: Cardiac MMRE is a promising and reproducible method for noninvasive assessment of diastolic LV stiffness and viscosity.Level of Evidence: 2Technical Efficacy: 1Keywords
This publication has 28 references indexed in Scilit:
- The Global Burden of Cardiovascular Diseases and RiskJACC, 2022
- Comparison of inversion methods inMRelastography: An open‐access pipeline for processing multifrequency shear‐wave data and demonstration in a phantom, human kidneys, and brainMagnetic Resonance in Medicine, 2022
- In vivo, high‐frequency three‐dimensional cardiac MR elastography: Feasibility in normal volunteersMagnetic Resonance in Medicine, 2016
- In vivo wideband multifrequency MR elastography of the human brain and liverMagnetic Resonance in Medicine, 2015
- Measuring age‐dependent myocardial stiffness across the cardiac cycle using MR elastography: A reproducibility studyMagnetic Resonance in Medicine, 2015
- Vibration‐synchronized magnetic resonance imaging for the detection of myocardial elasticity changesMagnetic Resonance in Medicine, 2012
- In vivo assessment of MR elastography‐derived effective end‐diastolic myocardial stiffness under different loading conditionsJournal of Magnetic Resonance Imaging, 2011
- Magnetic resonance elastography as a method for the assessment of effective myocardial stiffness throughout the cardiac cycleMagnetic Resonance in Medicine, 2010
- Magnetic resonance elastography: Inversions in bounded mediaMagnetic Resonance in Medicine, 2009
- MR elastography of the human heart: Noninvasive assessment of myocardial elasticity changes by shear wave amplitude variationsMagnetic Resonance in Medicine, 2008