Sensor manufacturer, temperature, and cyanobacteria morphology affect phycocyanin fluorescence measurements
- 27 October 2017
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (2) , 1079-1088
Abstract
Sensors to measure phycocyanin fluorescence in situ are becoming widely used as they may provide useful proxies for cyanobacterial biomass. In this study, we assessed five phycocyanin sensors from three different manufacturers. A combination of culture-based experiments and a 30–sample field study was used to examine the effect of temperature and cyanobacteria morphology on phycocyanin fluorescence. Phycocyanin fluorescence increased with decrease in temperature, although this varied with manufacturer and cyanobacterial density. Phycocyanin fluorescence and cyanobacterial biovolume were strongly correlated (R2 > 0.83, P < 0.05) for single-celled and filamentous species. The relationship was generally weak for a colonial strain of Microcystis aeruginosa. The colonial culture was divided into different colony size classes and phycocyanin measured before and after manual disaggregation. No differences were measured, and the observation that fluorescence spiked when large colonial aggregates drifted past the light source suggests that sample heterogeneity, rather than lack of light penetration into the colonies, was the main cause of the poor relationship. Analysis of field samples showed a strong relationship between in situ phycocyanin fluorescence and spectrophotometrically measured phycocyanin (R2 > 0.7, P < 0.001). However, there was only a weak relationship between phycocyanin fluorescence and cyanobacterial biovolume for two sensors (R2 = 0.22–0.29, P < 0.001) and a non-significant relationship for the third sensor (R2 = 0.29, P > 0.4). The five sensors tested in our study differed in their output of phycocyanin fluorescence, upper working limits (1200 to > 12,000 μg/L), and responses to temperature, highlighting the need for comprehensive sensor calibration and knowledge on the limitations of specific sensors prior to deployment.Keywords
Funding Information
- New Zealand Ministry of Business, Innovation and Employment (UOWX1503)
- Marsden Fund of the Royal Society of New Zealand (12-UOW-087)
- Waikato University Masters Scholarship
This publication has 27 references indexed in Scilit:
- Measurement of cyanobacteria using in-vivo fluoroscopy – Effect of cyanobacterial species, pigments, and coloniesWater Research, 2012
- EVALUATION OF IN SITU FLUOROMETRY TO DETERMINE CYANOBACTERIAL ABUNDANCE IN THE MURRAY AND LOWER DARLING RIVERS, AUSTRALIARiver Research and Applications, 2012
- Monitoring of potentially toxic cyanobacteria using an online multi-probe in drinking water sourcesJournal of Environmental Monitoring, 2011
- Use of in vivophycocyanin fluorescence to monitor potential microcystin-producing cyanobacterial biovolume in a drinkingwater sourceJournal of Environmental Monitoring, 2010
- Performance evaluation of phycocyanin probes for the monitoring of cyanobacteriaJournal of Environmental Monitoring, 2010
- A phycocyanin probe as a tool for monitoring cyanobacteria in freshwater bodiesJournal of Environmental Monitoring, 2007
- Detection and estimation of potentially toxic cyanobacteria in raw water at the drinking water treatment plant by in vivo fluorescence methodWater Research, 2007
- Measurement of phycocyanin fluorescenceas an online early warning system for cyanobacteria in reservoir intake waterEnvironmental Toxicology, 2005
- Freshwater phytoplankton quantification by chlorophyll a: a comparative study of in vitro, in vivo and in situ methodsWater Research, 2004
- Application of a submersible spectrofluorometer for rapid monitoring of freshwater cyanobacterial blooms: a case studyAquatic Microbial Ecology, 2002