Accuracy of 3‐T MRI using susceptibility‐weighted imaging to detect meniscal tears of the knee
- 13 May 2014
- journal article
- knee
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (1) , 198-204
Abstract
Purpose: To evaluate the diagnostic performance of susceptibility‐weighted imaging (SWI) at 3‐T magnetic resonance imaging for the assessment of meniscal tears.Methods: Ninety‐four patients with tears in the medial meniscus (31) or lateral meniscus (64) imaged with conventional magnetic resonance imaging and SWI followed by knee arthroscopy within 1 month were selected. The diagnostic values of SWI for the detection of meniscal tears were evaluated using arthroscopy as the reference standard. The sensitivity, specificity and accuracy between spin‐echo T1‐weighted imaging (T1WI) and fat‐suppressed proton density‐weighted imaging (FS‐PDWI) were compared. The diagnosis consistency with two radiologists was also compared. Receiver operating characteristic curve analyses were performed for each individual sequence to estimate their diagnostic performance in meniscal tear.Results: Analyses from 31 patients of medial meniscus tears showed that SWI achieved comparable performance with T1WI and FS‐PDWI with respect to sensitivity (96.8 vs. 93.5 and 89.2 %), specificity (66.7 vs. 66.7 and 66.7 %) and accuracy (91.9 vs. 89.2 and 93.5 %). In 64 patients of lateral meniscus tears, SWI was found to be a superior method over T1WI and FS‐PDWI with regard to sensitivity (98.4 vs. 92.2 and 95.3 %), specificity (100 vs. 100 and 100 %) and accuracy (98.5 vs. 92.5 and 95.5 %). Upon combination of these patients, SWI is similar or superior to T1WI and FS‐PDWI with sensitivity (97.9 vs. 92.6 and 94.7 %), specificity (77.8 vs. 77.8 and 77.8 %) and accuracy (96.2 vs. 89.2 and 93.3 %). SWI exhibited similar or better results with respect to sensitivity (97.9 vs. 92.6 and 94.7 %), specificity (77.8 vs. 77.8 and 77.8 %) and accuracy (96.2 vs. 89.2 and 93.3 %) over T1WI and FS‐PDWI.Conclusions: These data suggest that SWI can be used for the diagnosis of meniscal tears. The sensitivity, accuracy and negative predictive value were same as those of T1WI and FS‐PDWI according to the present study.Level of evidence: Diagnostic study, Level II.Keywords
This publication has 35 references indexed in Scilit:
- Improved Siderotic Nodule Detection in Cirrhosis with Susceptibility-Weighted Magnetic Resonance Imaging: A Prospective StudyPLOS ONE, 2012
- New MR sequences in daily practice: susceptibility weighted imaging. A pictorial essayInsights into Imaging, 2011
- Detection of normal spinal veins by using susceptibility‐weighted imagingJournal of Magnetic Resonance Imaging, 2009
- Imaging the vessel wall in major peripheral arteries using susceptibility‐weighted imagingJournal of Magnetic Resonance Imaging, 2009
- Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imagingJournal of Magnetic Resonance Imaging, 2009
- Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1American Journal of Neuroradiology, 2008
- Meniscal Measurements of T1ρand T2 at MR Imaging in Healthy Subjects and Patients with OsteoarthritisRadiology, 2008
- Medial Meniscus Extrusion on Knee MRI: Is Extent Associated with Severity of Degeneration or Type of Tear?American Journal of Roentgenology, 2004
- Meniscal Tear Configurations: Categorization with MR ImagingAmerican Journal of Roentgenology, 2003
- MR diagnosis of meniscal tears of the knee: value of fast spin-echo vs conventional spin-echo pulse sequences.American Journal of Roentgenology, 1994