Automated flow cytometric cell count and differentiation of canine cerebrospinal fluid cells using the ADVIA 2120
Authors:
- 20 August 2008
- journal article
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 37 (3) , 344-352
Abstract
Microscopic cell counts in cerebrospinal fluid (CSF) are time-consuming and prone to imprecision. The recently introduced automated hematology analyzer ADVIA 2120 offers an automated cell count and differential for CSF in the veterinary software mode based on laser light scatter and absorbance measurements. The purpose of this study was to evaluate the precision, linearity, and accuracy of the ADVIA 2120 CSF assay. Sixty-seven CSF samples were analyzed on the ADVIA 2120 and total nucleated cell counts (TNCC) and RBC counts were compared with the hemocytometer results. In 21 samples with TNCC >5/microL, ADVIA 2120 results were compared with 100-300 cell manual differentials performed on cytocentrifuged preparations. Statistical analysis included Spearman's rank correlation, Passing-Bablok regression, and Bland-Altman analysis. Repeatability (intra-assay) coefficients of variation (CVs) ranged from 4.19% to 25.94%. Interassay CVs ranged from 2.56% to 28.67%. Accurate results within 30% were achieved for TNCC up to 4000/microL. Except for low TNCC, deviation from the expected value was higher (TNCC of 8/microL instead of 4/microL). The following correlation coefficients (r) and biases were achieved compared with the reference method: r=.90 and bias 2.3/microL for TNCC; r=.88 and bias 32.0/microL for RBC counts; r=.86 and bias +/-13.4% for mononuclear and polymorphonuclear cell percentages; r=.88 and bias -6.1% for lymphocyte percentage; r=.56 and bias 19.4% for monocyte percentage; and r=.75 and bias -9.7% for neutrophil percentage. Our results demonstrated that the automated ADVIA 2120 CSF assay generally compares well with reference methods although there are some limitations for the automated monocyte count and for samples with only mild pleocytosis.Keywords
This publication has 9 references indexed in Scilit:
- Is the inherent imprecision of manual leukocyte differential counts acceptable for quantitative purposes?Veterinary Clinical Pathology, 2006
- The ADVIA 2120 Hematology System: Flow Cytometry-Based Analysis of Blood and Body Fluids in the Routine Hematology LaboratoryLaboratory Hematology, 2005
- Evaluation of ADVIA 120 CSF assay (BayerR) vs. chamber counting of cerebrospinal fluid specimensClinical and Laboratory Haematology, 2004
- CEREBROSPINAL FLUID ANALYSIS2004
- EOSINOPHILIC MENINGOENCEPHALITIS DUE TO TOXOCARA CANIS: CASE REPORT AND REVIEW OF THE LITERATUREThe American Journal of Tropical Medicine and Hygiene, 2003
- Automated Counting of Cells in Cerebrospinal Fluid Using the CellDyn-4000 Haematology AnalyserClinical Chemistry and Laboratory Medicine (CCLM), 2002
- Automated counting of white and red blood cells in the cerebrospinal fluidClinical and Laboratory Haematology, 2000
- Leukocyte Counts in Cerebrospinal Fluid with the Automated Hematology Analyzer CellDyn 3500 and the Urine Flow Cytometer UF-100Clinical Chemistry, 2000
- Electronic Counting of Spinal Fluid CellsAmerican Journal of Clinical Pathology, 1984