Effects of Differential Magnetic Field/Tensor and Redundant Measurements on Multi-DOF Motion Estimation of a Magnetic Sensing System
- 5 June 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 16633-16644
Abstract
This paper presents a multi-DOF motion sensing system consisting of a permanent magnet (PM) and a magnetic tensor sensor (MTS) comprising a 3×3 array of three-axis digital magnetic flux density (MFD) sensors, and the methods to measure their relative MTS-PM position/ orientation in a 3D space. The design enables redundant differential measurements of MFD vectors and gradient tensor components to account for the singularities due to matrix inversion, providing a basis to explore different methods for multi-DOF estimation of the PM position/ pose. Formulated as a two-stage linear least-square (LS) problem to take advantage of the dipole simplicity and exploit its physics revealed by its inverse model to guide the design of a fully connected artificial neural network (ANN) to account for the MTS measurement noise and un-modeled factors, a prototype multi-MTS system capable of 5-DOF motion measurements is developed and evaluated experimentally along with a study analyzing the parametric effects on the estimation accuracy; both stationary and moving sensor scenarios are considered. Enhanced with a fully connected ANN, an accuracy within a root-mean-square error (RMSE) of 40μm spatial position and 0.1° pose can be uniquely obtained without subtracting a predetermined geomagnetic field in both fixed and moving multi-MTS scenarios, representing a significant improvement over the (0.5mm, 1°) RMSE of the single-MTS.Keywords
Funding Information
- National Science Foundation of China (U1713204)
- U.S. National Science Foundation (EFRI-M3C-1137172, CMMI-1662700)
- Georgia Tech by China Scholarship Council
This publication has 19 references indexed in Scilit:
- Design and optimization of sensor array for magnetic gradient tensor systemSensor Review, 2019
- Review of anatomy-based ankle–foot robotics for mind, motor and motion recovery following stroke: design considerations and needsInternational Journal of Intelligent Robotics and Applications, 2018
- Magnetic Tensor Sensor for Gradient-Based Localization of Ferrous Object in Geomagnetic FieldIEEE Transactions on Magnetics, 2016
- A novel way-finding method based on geomagnetic field effects and magnetic tensor measurements for visually impaired users2015
- Moore–Penrose generalized inverse of the gradient tensor in Euler's equation for locating a magnetic dipoleJournal of Applied Physics, 2014
- Magnetic dipole localization based on magnetic gradient tensor data at a single pointJournal of Applied Remote Sensing, 2014
- Small Magnetic Sensors for Space ApplicationsSensors, 2009
- A Closed-Form Formula for Magnetic Dipole Localization by Measurement of Its Magnetic Field and Spatial GradientsIEEE Transactions on Magnetics, 2006
- Magnetic sensors and their applicationsIEEE Sensors Journal, 2006
- Magnetic dipole localization with a gradiometer: obtaining unique solutions2002