In vitro blood sample assessment: investigating correlation of laboratory hemoglobin and spectral properties of dual-energy CT measurements (ρ/Z)
Open Access
- 10 June 2024
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 34 (12) , 7934-7943
Abstract
Objectives: Our study comprised a single-center retrospective in vitro correlation between spectral properties, namely ρ/Z values, derived from scanning blood samples using dual-energy computed tomography (DECT) with the corresponding laboratory hemoglobin/hematocrit (Hb/Hct) levels and assessed the potential in anemia-detection. Methods: DECT of 813 patient blood samples from 465 women and 348 men was conducted using a standardized scan protocol. Electron density relative to water (ρ or rho), effective atomic number (Zeff), and CT attenuation (Hounsfield unit) were measured. Results: Positive correlation with the Hb/Hct was shown for ρ (r-values 0.37–0.49) and attenuation (r-values 0.59–0.83) while no correlation was observed for Zeff (r-values −0.04 to 0.08). Significant differences in attenuation and ρ values were detected for blood samples with and without anemia in both genders (p value < 0.001) with area under the curve ranging from 0.7 to 0.95. Depending on the respective CT parameters, various cutoff values for CT-based anemia detection could be determined. Conclusion: In summary, our study investigated the correlation between DECT measurements and Hb/Hct levels, emphasizing novel aspects of ρ and Zeff values. Assuming that quantitative changes in the number of hemoglobin proteins might alter the mean Zeff values, the results of our study show that there is no measurable correlation on the atomic level using DECT. We established a positive in vitro correlation between Hb/Hct values and ρ. Nevertheless, attenuation emerged as the most strongly correlated parameter with identifiable cutoff values, highlighting its preference for CT-based anemia detection. Clinical relevance statement: By scanning multiple blood samples with dual-energy CT scans and comparing the measurements with standard laboratory blood tests, we were able to underscore the potential of CT-based anemia detection and its advantages in clinical practice. Key Points: Prior in vivo studies have found a correlation between aortic blood pool and measured hemoglobin and hematocrit. Hemoglobin and hematocrit correlated with electron density relative to water and attenuation but not Zeff. Dual-energy CT has the potential for additional clinical benefits, such as CT-based anemia detection. GraphicalKeywords
Funding Information
- Guerbet AG, Switzerland (N/A)
This publication has 40 references indexed in Scilit:
- Technical principles of dual source CTEuropean Journal of Radiology, 2008
- Radiological profile of anemia on unenhanced MDCT of the thoraxEuropean Radiology, 2008
- The Effects of Radiation Dose and CT Manufacturer on Measurements of Lung DensitometryChest, 2007
- Observer Performance in Assessing Anemia on Thoracic CTAmerican Journal of Roentgenology, 2005
- Storage of Serum or Whole Blood Samples? Effects of Time and Temperature on 22 Serum AnalytesClinical Chemistry and Laboratory Medicine (CCLM), 1995
- Diagnosis of anemia on computed tomography scans of the thoraxJournal of Computed Tomography, 1988
- The unreliability of CT numbers as absolute valuesAmerican Journal of Roentgenology, 1982
- Measurement of effective atomic number and electron density using an EMI scannerNeuroradiology, 1976
- Human HaemoglobinsJournal of Medical Genetics, 1965
- IS HEMOGLOBIN AN ESSENTIAL STRUCTURAL COMPONENT OF HUMAN ERYTHROCYTE MEMBRANES?*Journal of Clinical Investigation, 1963