Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging
Authors:
- Heng LiHLHeng Li
- Radhe MohanRMRadhe Mohan
- X Ronald ZhuXZX Ronald Zhu
- 7 November 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (23) , 6729-6748
Abstract
The clinical applications of kilovoltage x-ray cone-beam computed tomography (CBCT) have been compromised by the limited quality of CBCT images, which typically is due to a substantial scatter component in the projection data. In this paper, we describe an experimental method of deriving the scatter kernel of a CBCT imaging system. The estimated scatter kernel can be used to remove the scatter component from the CBCT projection images, thus improving the quality of the reconstructed image. The scattered radiation was approximated as depth-dependent, pencil-beam kernels, which were derived using an edge-spread function (ESF) method. The ESF geometry was achieved with a half-beam block created by a 3 mm thick lead sheet placed on a stack of slab solid-water phantoms. Measurements for ten water-equivalent thicknesses (WET) ranging from 0 cm to 41 cm were taken with (half-blocked) and without (unblocked) the lead sheet, and corresponding pencil-beam scatter kernels or point-spread functions (PSFs) were then derived without assuming any empirical trial function. The derived scatter kernels were verified with phantom studies. Scatter correction was then incorporated into the reconstruction process to improve image quality. For a 32 cm diameter cylinder phantom, the flatness of the reconstructed image was improved from 22% to 5%. When the method was applied to CBCT images for patients undergoing image-guided therapy of the pelvis and lung, the variation in selected regions of interest (ROIs) was reduced from >300 HU to <100 HU. We conclude that the scatter reduction technique utilizing the scatter kernel effectively suppresses the artifact caused by scatter in CBCT.Keywords
This publication has 30 references indexed in Scilit:
- Characterization of scattered radiation in kV CBCT images using Monte Carlo simulationsMedical Physics, 2006
- Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CTPhysics in Medicine & Biology, 2006
- TH-D-ValA-05: Effect of Measured Cone-Beam CT-Density Calibration On Dose CalculationsMedical Physics, 2006
- Optical blur and collection efficiency in columnar phosphors for X-ray imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Regularization method for scatter‐glare correction in fluoroscopic imagesMedical Physics, 1999
- Extraction of primary signal from EPIDs using only forward convolutionMedical Physics, 1997
- 3-D image reconstruction with veiling glare correction to improve the contrast of 3-D reconstructed vascular imagesIEEE Transactions on Nuclear Science, 1996
- Scatter compensation in digital chest radiography using the posterior beam stop techniqueMedical Physics, 1994
- Scatter Compensation for Digital Chest Radiography Using Maximum Likelihood Expectation MaximizationInvestigative Radiology, 1993
- Scatter estimation for a digital radiographic system using convolution filteringMedical Physics, 1987