Full-Field Calcium K-Edge X-ray Absorption Near-Edge Structure Spectroscopy on Cortical Bone at the Micron-Scale: Polarization Effects Reveal Mineral Orientation
- 22 March 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (7) , 3826-3835
Abstract
Here we show results on X-ray absorption near edge structure spectroscopy in both transmission and X-ray fluorescence full-field mode (FF-XANES) at the calcium K-edge on human bone tissue in healthy and disease conditions and for different tissue maturation stages. We observe that the dominating spectral differences originating from different tissue regions, which are well pronounced in the white line and post-edge structures are associated with polarization effects. These polarization effects dominate the spectral variance and must be well understood and modeled before analyzing the very subtle spectral variations related to the bone tissue variations itself. However, these modulations in the fine structure of the spectra can potentially be of high interest to quantify orientations of the apatite crystals in highly structured tissue matrices such as bone. Due to the extremely short wavelengths of X-rays, FF-XANES overcomes the limited spatial resolution of other optical and spectroscopic techniques exploiting visible light. Since the field of view in FF-XANES is rather large the acquisition times for analyzing the same region are short compared to e.g. X-ray diffraction techniques. Our results on the angular absorption dependence were verified by both site-matched polarized Raman spectroscopy which has been shown to be sensitive to the orientation of bone building blocks and by mathematical simulations of the angular absorbance dependence. As an outlook we further demonstrate the polarization based assessment of calcium- containing crystal orientation and specification of calcium in a beta-tricalcium phosphate (β-Ca3(PO4)2 scaffold implanted into ovine bone. Regarding the use of XANES to assess chemical properties of Ca in human bone tissue our data suggest that neither the anatomical site (tibia vs. jaw) nor pathology (healthy vs. necrotic jaw bone tissue) affected the averaged spectral shape of the XANES spectra.Keywords
This publication has 35 references indexed in Scilit:
- The Mineral–Collagen Interface in BoneCalcified Tissue International, 2015
- Canalicular Network Morphology Is the Major Determinant of the Spatial Distribution of Mass Density in Human Bone Tissue: Evidence by Means of Synchrotron Radiation Phase-Contrast nano-CTJournal of Bone and Mineral Research, 2014
- Alterations of Mass Density and 3D Osteocyte Lacunar Properties in Bisphosphonate-Related Osteonecrotic Human Jaw Bone, a Synchrotron µCT StudyPLOS ONE, 2014
- XANES analysis of dried and calcined bonesMaterials Science and Engineering: C, 2013
- Architecture of the osteocyte network correlates with bone material qualityJournal of Bone and Mineral Research, 2013
- The nanometre-scale physiology of bone: steric modelling and scanning transmission electron microscopy of collagen–mineral structureJournal of The Royal Society Interface, 2012
- Nature’s hierarchical materialsProgress in Materials Science, 2007
- Structure and mechanical quality of the collagen–mineral nano-composite in boneJournal of Materials Chemistry, 2004
- TEM analysis of the nanostructure of normal and osteoporotic human trabecular boneBone, 2003
- Mechanical properties and the hierarchical structure of boneMedical Engineering & Physics, 1998