Abstract
The study presents an optimized pressure-sensitive paint (PSP) measurement system that was applied to investigate unsteady surface pressures on recently developed double-swept rotor blades in the rotor test facility at the German Aerospace Center (DLR) in Göttingen. The measurement system featured an improved version of a double-shutter camera that was designed to reduce image blur in PSP measurements on fast rotating blades. It also comprised DLR’s PSP sensor, developed to capture transient flow phenomena (iPSP). Unsteady surface pressures were acquired across the outer 65% of the rotor blade with iPSP and at several radial blade sections by fast-response pressure transducers at blade-tip Mach and Reynolds numbers of $$\mathrm {M}_\mathrm{tip} = 0.282-0.285$$ and $$\mathrm {Re}_\mathrm{tip}= 5.84-5.95 \times 10^5$$ . The unique experimental setup allowed for scanning surface pressures across the entire pitch cycle at a phase resolution of $${0.225}\,{\mathrm{deg}}$$ azimuth for different collective and cyclic-pitch settings. Experimental results of both investigated cyclic-pitch settings are compared in detail to a delayed detached eddy simulation using the flow solver FLOWer and to flow visualizations from unsteady Reynolds-averaged Navier–Stokes (URANS) computations with DLR’s TAU code. The findings reveal a detailed and yet unseen insight into the pressure footprint of double-swept rotor blades undergoing dynamic stall and allow for deducing “stall maps”, where confined areas of stalled flow on the blade are identifiable as a function of the pitch phase. Graphical
Keywords
Funding Information
- Horizon 2020 (945583)
- Deutsches Zentrum für Luft- und Raumfahrt (URBAN Rescue)
- Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR)
This publication has 43 references indexed in Scilit:
- A fast double shutter system for CCD image sensorsMeasurement Science and Technology, 2014
- Single-shot, lifetime-based pressure-sensitive paint for rotating bladesMeasurement Science and Technology, 2011
- Transition Point Detection from the Surface Pressure Distribution for Controller DesignJournal of Aircraft, 2008
- Block Structured Navier-Stokes Solver FLOWer2006
- Application of pressure-sensitive paint for determination of the pressure field and calculation of the forces and moments of models in a wind tunnelExperiments in Fluids, 2005
- Porous Polymer/Ceramic Composites for Luminescence-Based Temperature and Pressure MeasurementMRS Proceedings, 1999
- A Qualitative Examination of Dynamic Stall from Flight Test DataJournal of the American Helicopter Society, 1998
- Pressure-sensitive paint in aerodynamic testingExperimental Thermal and Fluid Science, 1995
- On the identification of a vortexJournal of Fluid Mechanics, 1995
- Triangulation With Expanded Range Of DepthOptical Engineering, 1985