Measurements of AIM for Visible Wavelength Based on Individual Eye Model
Authors:
- 29 November 2006
- journal article
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 23 (12) , 3263-3266
Abstract
We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.Keywords
This publication has 7 references indexed in Scilit:
- Phase-Space Analysis of Wavefront Coding Imaging SystemsChinese Physics Letters, 2006
- Correlation between Post-LASIK Starburst Symptom and Ocular Wavefront AberrationsChinese Physics Letters, 2006
- Wave-Front Aberrations of Cornea and Crystalline LensChinese Physics Letters, 2006
- Optical Image Contrast Reversal Using Bacteriorhodopsin FilmsChinese Physics Letters, 2005
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994
- Retrospective evaluation of alternative vision screening criteria for older and younger driversAccident Analysis & Prevention, 1993
- Contrast sensitivity, acuity, and the perception of 'real-world' targets.British Journal of Ophthalmology, 1987