Cyclosporine Serum Concentrations Soon After Heart or Heart‐Lung Transplantation
Authors:
- 12 November 1986
- journal article
- research article
- Published by Wiley in The Journal of Clinical Pharmacology
- Vol. 26 (8) , 652-657
Abstract
The accumulation of cyclosporine was evaluated in 11 patients following either heart or heart‐lung transplantation. Blood samples were drawn frequently for the first few postoperative days, and the plasma was analyzed by both radioimmunoassay (RIA) and high‐performance liquid chromatography (HPLC). The levels determined by RIA were higher than those assessed by HPLC, and it is hypothesized that the difference is due to antibody reactive metabolites of cyclosporine, which are measured by the RIA procedure. We did not find any consistent trends in the accumulation of these metabolites. Analysis of early clinical data did not suggest any relationship between levels of cyclosporine or its metabolites and clinical outcome.Keywords
This publication has 6 references indexed in Scilit:
- Cyclosporine Blood Concentrations Determined by Specific Versus Nonspecific Assay MethodsThe Journal of Clinical Pharmacology, 1986
- Disposition of cyclosporine in several animal species and man. I. Structural elucidation of its metabolites.Drug Metabolism and Disposition, 1984
- Simple and rapid high-performance liquid chromatographic analysis of cyclosporine in human blood and serumJournal of Chromatography B: Biomedical Sciences and Applications, 1984
- Simplified liquid-chromotographic analysis for cyclosporin A, and comparison with radioimmunoassay.Clinical Chemistry, 1983
- Cyclosporin A: correlation between HPLC and RIA serum levelsInternational Journal of Clinical Pharmacy, 1982
- A Radioimmunoassay to Measure Cyclosporin a in Plasma and Serum SamplesJournal of Immunoassay, 1981