Intraoperative Testing of the Implantable Cardioverter‐Defibrillator: How Much Is Enough?
Authors:
- 10 October 2005
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (2) , 140-145
Abstract
Introduction: Defibrillation testing of the implantable cardioverter‐defibrillator (ICD) is considered a standard and required practice at the time of implantation. How much testing, if any in some cases, should be performed, however, remains unknown. Methods and Results: Included in this retrospective analysis were 835 patients (77% men; age 65 ± 13 years) who received transvenous ICDs between January 1996 and December 2003. One hundred twenty‐nine (15.5%) had intraoperative defibrillation threshold (DFT) testing, 503 (60.2%) had limited defibrillation safety margin testing, and 203 (24.3%) had no defibrillation testing. We compared the outcome (success of ICD therapies against spontaneous VT/VF events and survival) of the three groups of patients, who in some respects had important clinical differences. The success of the first delivered shocks against VT/VF was similar for DFT (91%), safety margin testing (91%), and no‐testing (92%) groups; and the second shocks terminated the remaining episodes in all three groups. Sudden‐death‐free survival rates were similar in the three groups, however, the overall long‐term survival rate was significantly lower in the no‐testing group (58%) than in the DFT (74%) and safety margin testing (69%) groups (P < 0.0005). Multivariate analysis found no strong predictors of sudden death, but there were several independent predictors of overall mortality including lack of ICD testing (HR: 2.031, CI: 1.253–3.290, P = 0.004). Conclusion: In this select patient cohort, success of ICD therapies and sudden‐death‐free survival were similar in patients who had DFT, safety margin testing, and no testing, but overall survival was significantly lower in the no‐testing group. Thus in the absence of prospective mortality data, a minimum of safety margin ICD testing should remain standard practice.Keywords
This publication has 27 references indexed in Scilit:
- One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: An analysis from the Low Energy Safety Study (LESS)Heart Rhythm, 2005
- Clinical competency statement: Training pathways for implantation of cardioverter defibrillators and cardiac resynchronization devicesHeart Rhythm, 2004
- High Defibrillation Thresholds in Transvenous Biphasic Implantable Defibrillators:Pacing and Clinical Electrophysiology, 2003
- Sudden Death in Recipients of Transvenous Implantable Cardioverter Defibrillator Systems:Journal of Cardiovascular Electrophysiology, 1999
- Predictors of Outcome in Patients with Implantable Cardioverter DefibrillatorsCardiology, 1998
- Transvenous Defibrillation Lead SystemsJournal of Cardiovascular Electrophysiology, 1996
- Safety of implantation of a cardioverter-defibrillator without general anesthesia in an electrophysiology laboratoryThe American Journal of Cardiology, 1995
- Comparison of implantation of nonthoracotomy defibrillators in the operating room versus the electrophysiology laboratoryThe American Journal of Cardiology, 1995
- Patients with a high defibrillation threshold: Clinical characteristics, management, and outcomeAmerican Heart Journal, 1991
- Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillatorThe American Journal of Cardiology, 1988