Wear of different materials for total hip replacement under adverse stop-dwell-start in vitro wear simulation conditions
Authors:
- 19 November 2018
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 232 (12) , 1261-1270
Abstract
Hip simulation is a common technique for pre-clinical evaluation of wear performance of total hip arthroplasty. Standard techniques replicate kinematics of walking patterns of a typical patient. Attention has focussed in developing simulations of other typical patient daily activities to improve accuracy of wear predictions. A method for simulating stop-dwell-start motion during patient walking and the effect on 36-mm metal-on-metal total hip arthroplasty was previously presented by the authors. This study sought to extend the previous work to look at the effect of these conditions on ceramic-on-ceramic, metal-on-polyethylene and ceramic-on-polyethylene bearings. Two stop-dwell-start protocols were used: one reproducing average patient movement patterns and one examining more severe conditions. For all materials tested, no significant increase in wear was observed under average stop-dwell-start conditions, suggesting the bearing types tested are robust to this type of activity. A significant increase in wear was observed for metal-on-metal, metal-on-polyethylene and ceramic-on-polyethylene bearings under severe stop-dwell-start conditions, this was attributed to depletion of lubricant in the bearing during the dwell period. A greater relative increase in wear was observed for metal-on-metal bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings. This may be explained by the contributions of the different lubrication mechanisms in each bearing type. Wear of ceramic-on-ceramic was very low in all tests, suggesting normal measurement variation was masking any effect of the adverse conditions. It was not possible to determine any effect of the different activities. These results emphasise the importance of exploring adverse patient activity simulations. The increase in wear rate associated with an adverse activity such as seen in stop-dwell-start motion, has to be considered in the context of the frequency of the adverse activity cycle relative to other activities such as standard continuous walking, to determine the impact on the total wear in a given time period.Keywords
This publication has 21 references indexed in Scilit:
- Wear Performance of Ceramic-On-Metal Hip BearingsPLOS ONE, 2013
- Tribology and total hip joint replacement: Current concepts in mechanical simulationMedical Engineering & Physics, 2008
- Effect of start-up conditions on elastohydrodynamic lubrication of metal-on-metal hip implantsProceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2006
- A hip joint simulator study of the performance of metal-on-metal jointsThe Journal of Arthroplasty, 2004
- Comparison of in vitro with in vivo characteristics of wear particles from metal–metal hip implantsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulatorWear, 2001
- Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal ImplantsClinical Orthopaedics and Related Research, 1996
- Elastohydrodynamic Lubrication of Elliptical Contacts for Materials of Low Elastic Modulus I—Fully Flooded ConjunctionJournal of Lubrication Technology, 1978
- ARTHROPLASTY OF THE HIP A New OperationThe Lancet, 1961