Trident: Three-dimensional ray tracing for modeling high intensity focused ultrasound ablation
- 1 April 2025
- journal article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 157 (4) , 3005-3016
Abstract
The lack of magnetic resonance (MR)–based thermometry in fat and bone poses significant challenges for temperature control in high intensity focused ultrasound (HIFU) ablation treatment. This paper introduces Trident, a ray tracing method to calculate the spatial heat production during HIFU, handling both longitudinal and shear waves in isotropic solids. Trident is especially advantageous for setups with complex geometries where other numerical methods prove computationally prohibitive. It outperforms current state-of-the-art ray tracing techniques by being at least 20 times faster without sacrificing accuracy. Conversely, when given the same running time, it can achieve 2 orders of magnitude higher accuracy. The improvement is due to the specially developed approach that captures the intensity decrease due to geometrical spreading in an efficient way. Trident was validated against a known reference method and temperature measurements on bovine cortical bone during HIFU sonication. Results indicate a good agreement with experimental temperature measurements. In highly attenuating solid cortical bone, the Trident method was able to model temperature increases within 3 K of peak temperatures measured by optical probes.Keywords
Funding Information
- Stichting voor de Technische Wetenschappen (15179)
This publication has 32 references indexed in Scilit:
- Model predictive control for MR-HIFU-mediated, uniform hyperthermiaInternational Journal of Hyperthermia, 2019
- Ultrasound thermal monitoring with an external ultrasound source for customized bipolar RF ablation shapesInternational Journal of Computer Assisted Radiology and Surgery, 2018
- Simulating thermal effects of MR‐guided focused ultrasound in cortical bone and its surrounding tissueMedical Physics, 2017
- Ultrasound-guided tissue fractionation by high intensity focused ultrasound in an in vivo porcine liver modelProceedings of the National Academy of Sciences, 2014
- MR thermometryJournal of Magnetic Resonance Imaging, 2008
- High intensity focused ultrasound: Physical principles and devicesInternational Journal of Hyperthermia, 2007
- Longitudinal and shear mode ultrasound propagation in human skull boneUltrasound in Medicine & Biology, 2006
- Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studiesInternational Journal of Hyperthermia, 2005
- Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effectsMagnetic Resonance in Medicine, 1995
- On the propagation of weak shock wavesJournal of Fluid Mechanics, 1956