Development and Assessment of Poly(ethylene glycol) Diacrylate-Embedded Metalloporphyrin for Phosphorescence Lifetime-Based In Vivo Monitoring of Oxygen Tension
- 4 September 2026
- journal article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (10) , 8925-8936
Abstract
The timely detection of ischemia is crucial for enhancing outcomes in reconstructive surgery. This study presents the development and in vivo evaluation of a metalloporphyrin-based phosphorescence lifetime oxygen sensor embedded in poly(ethylene glycol) diacrylate (PEGDA) hydrogel for monitoring local tissue oxygen tension (TOT). Palladium(II) tetraphenyltetrabenzoporphyrin was incorporated into microporous PEGDA hydrogels using polystyrene to facilitate dispersion and enhance photophysical properties. Sensors were calibrated under controlled oxygen conditions and characterized for oxygen-dependent phosphorescence lifetime response. In vivo performance was assessed using rat flap models and a swine tongue ischemia model. Implant localization and local tissue response were evaluated using luminescence imaging and histological analysis. The sensors demonstrated an inverse relationship between phosphorescence lifetime and pO2, with a dynamic response to experimentally varied oxygen conditions. In vivo, the sensors detected regional oxygen differences associated with ischemia and areas that later developed tissue necrosis in flap models. In the rat pedicle flap model, a decrease in oxygenation was detected within approximately 70 s of vascular clamping. In the swine tongue model, sensors detected acute oxygenation changes during vascular compromise and partial recovery after tourniquet release and tongue massage. Implants remained localized without visible migration, and histological analysis showed no granulomatous inflammation or multinucleated giant-cell reaction over the 28-day study period. This injectable PEGDA-embedded metalloporphyrin sensor enables non-invasive phosphorescence lifetime-based monitoring of local tissue oxygen tension after implantation. Its oxygen-responsive lifetime behavior, short-term positional stability, and proof-of-concept ischemia detection support further development as a localized monitoring tool for surgical tissue viability.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (F32HL120650)
- Plastic Surgery Foundation (310323)
- Duke University
- Kenan Plastic Surgery Research Labs
This publication has 26 references indexed in Scilit:
- Strategies Following Free Flap Failure in Lower Extremity Trauma: A Systematic ReviewJPRAS Open, 2023
- What is new in microcirculation and tissue oxygenation monitoring?Journal of Clinical Monitoring and Computing, 2022
- Detection of flap tissue ischemia in a rat model: Real-time monitoring of changes in oxygenation and perfusion through injectable biosensorsSurgery, 2020
- Spectrofluorimetric study on fluorescence quenching of tyrosine and l‐tryptophan by the aniracetam cognition enhancer drug: quenching mechanism using Stern–Volmer and double‐log plotsLuminescence, 2020
- Tissue-Integrating Oxygen Sensors: Continuous Tracking of Tissue Hypoxia2017
- Ischemia/Reperfusion2016
- Indicators for optical oxygen sensorsBioanalytical Reviews, 2012
- Tongue Necrosis: A Rare Complication of Oral IntubationThe Laryngoscope, 2010
- Oxygen Dependent Quenching of Phosphorescence1996
- Recovery of Oxygen Distributions in Tissue from Phosphorescence Decay Data1994