Cardiovascular stent design and wall shear stress distribution in coronary stented arteries
Authors:
- 31 May 2012
- journal article
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 7 (5) , 430-433
Abstract
The stent is a major breakthrough in the treatment of coronary artery diseases. The permanent vascular implant of a stent, however, changes the intra-stent blood flow haemodynamics. There is a growing consensus that the stent implant may change the artery wall shear stress distribution and hence trigger the restenosis process. Computational fluid dynamics (CFD) has been widely used to analyse haemodynamics in stented arteries. In this Letter, CFD models were developed to investigate the effects of stent design pattern and strut geometry, respectively, on the wall shear stress distribution in coronary stented arteries. Assessment of the potential restenosis risk was primarily based on the wall shear stress distribution. Results show that the stent design pattern alone does not have a significant impact on the stent haemodynamic behaviour. Wall shear stress is very sensitive to strut thickness, while varying the strut width or crown radius has very little effect. The proposed methodology and findings will provide great insight for future optimisation of stent design to reduce the risk of restenosis.Keywords
This publication has 12 references indexed in Scilit:
- Why Similar Stent Designs Cause New Clinical IssuesJACC: Cardiovascular Interventions, 2012
- Papel de la tensión de cizallamiento en la enfermedad aterosclerótica y la reestenosis tras implantación de stent coronarioRevista Espanola de Cardiologia, 2006
- Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteriesAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Effect of Endothelial Shear Stress on the Progression of Coronary Artery Disease, Vascular Remodeling, and In-Stent Restenosis in HumansCirculation, 2003
- Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stentsAmerican Heart Journal, 2001
- Restenosis after coronary placement of various stent typesThe American Journal of Cardiology, 2001
- Hemodynamic Shear Stress and Its Role in AtherosclerosisJAMA, 1999
- Laminar Shear StressArteriosclerosis, Thrombosis, and Vascular Biology, 1998
- BLOOD FLOW IN ARTERIESAnnual Review of Fluid Mechanics, 1997
- Intimal thickening under shear in a carotid bifurcation—A numerical studyJournal of Biomechanics, 1996