Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes
- 1 January 2013
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (1) , 169-174
Abstract
Patient-specific instrumentation potentially improves surgical precision and decreases operative time in total knee arthroplasty (TKA) but there is little supporting data to confirm this presumption. We asked whether patient-specific instrumentation would require infrequent intraoperative changes to replicate a single surgeon’s preferences during TKA and whether patient-specific instrumentation guides would fit securely. We prospectively evaluated the plan and surgery in 60 patients treated with 66 TKAs performed with patient-specific instrumentation and recorded any changes. A subset of six postoperative radiographic changes to the femoral and tibial components (implant size, coronal and sagittal alignment) was analyzed to determine if surgeon intervention was beneficial. Each guide was evaluated to determine fit. We compared patient demographics and implant sizing in the patient-specific instrumentation group with a control group in which traditional instrumentation was used. We recorded 161 intraoperative changes in 66 knee arthroplasties (2.4 changes/knee) performed with patient-specific instrumentation. The predetermined implant size was changed intraoperatively in 77% of femurs and 53% of tibias. We identified a subset of 95 intraoperative changes that could be radiographically evaluated to determine if our changes were an improvement or detriment to reaching goal alignment. Eighty-two of the 95 changes (86%) made by the surgeon were an improvement to the recommended alignment or size of patient-specific instrumentation. The guide did not fit securely on eight femurs (12%) and three tibias (5%). Tourniquet time and blood loss were not improved with patient-specific instrumentation. We caution surgeons against blind acceptance of patient-specific instrumentation technology without supportive data. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 17 references indexed in Scilit:
- A Resident Survey Study of Orthopedic Fellowship Specialty Decision Making and Views on Arthroplasty as a CareerThe Journal of Arthroplasty, 2011
- Joint Replacement Access in 2016The Journal of Arthroplasty, 2010
- Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignmentInternational Orthopaedics, 2008
- Custom-Fit Total Knee Arthroplasty (OtisKnee) Results in MalalignmentThe Journal of Arthroplasty, 2008
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Long-Term Results of Total Condylar Knee ArthroplastyThe Journal of Arthroplasty, 2005
- Prevalence of Primary and Revision Total Hip and Knee Arthroplasty in the United States From 1990 Through 2002Journal of Bone and Joint Surgery, 2005
- Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 2001
- Total Condylar Knee ReplacementClinical Orthopaedics and Related Research, 2001
- Survivorship analysis of cemented total condylar knee arthroplastyThe Journal of Arthroplasty, 1996