Precision of implementing virtual setups for orthodontic treatment using CAD/CAM-fabricated custom archwires
- 11 January 2016
- journal article
- clinical trial
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 77 (1) , 1-8
Abstract
The SureSmile® process (OraMetrix®; Richardson, TX, USA) utilizes computer-aided design and computer-aided manufacturing (CAD/CAM). A virtual setup is created for treatment planning and chairside implementation using custom archwires fabricated by robots. The objective of this study was to determine the precision of this implementation. The setup models of 26 consecutive patients were compared to models of the final outcome. Using a virtual matching process, the planned and the achieved tooth positions were superimposed and the differences between them calculated along three translational planes and three rotational axes, thus, yielding six deviation values for each tooth. The median deviations were 0.19–0.21 mm based on translational movements and 1.77°–3.04° based on rotational movements. The precision of implementing the setups decreased from anterior to posterior, with incisors showing the best outcomes. Virtual setups can be implemented in a clinically successful fashion with custom archwires fabricated by CAD/CAM in accordance with the SureSmile® process.Keywords
This publication has 20 references indexed in Scilit:
- Ergebnisqualität von Laborprozessen in der Lingualtechnik: Vergleich der gängigen VerfahrenInformationen aus Orthodontie & Kieferorthopädie, 2012
- Accuracy in tooth positioning with a fully customized lingual orthodontic applianceAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Accuracy of invisalign® treatments in the anterior tooth regionJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2011
- Therapeutic Accuracy of Individualized Brackets in Lingual OrthodonticsJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2010
- How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with InvisalignAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Klinische Umsetzbarkeit eines Setups in der lingualen OrthodontieInformationen aus Orthodontie & Kieferorthopädie, 2008
- On bracket slot height: A methodologic studyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1998
- Variations in bracket placement in the preadjusted orthodontic applianceAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1992
- Three biologic variables modifying faciolingual tooth angulation by straight-wire appliancesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1989
- Variability in three morphologic features of the permanent maxillary central incisorAmerican Journal of Orthodontics, 1984