Comparison of bioimpedance spectroscopy and dual energy X-ray absorptiometry for assessing body composition changes in obese children during weight loss
Authors:
- 11 September 2020
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 75 (1) , 73-84
Abstract
Background Obesity and age influence the reliability of dual energy X-ray absorptiometry scanning (DEXA) and bioimpedance spectroscopy (BIS). Both are used in clinical settings, but have not been compared for measurements in obese children. We compared DEXA and BIS for evaluating body composition and inherent changes in obese children before and after a 10-month weight loss programme. Methods DEXA and BIS were used to evaluate 130 patients at baseline and 75 at follow-up. We tested agreement between the two techniques using Bland–Altman plots and proportional bias using Passing–Bablok regressions. Results The Bland–Altman plots showed wide agreement limits before and after weight loss and when monitoring longitudinal changes. At baseline, the Passing–Bablok regressions revealed a proportional bias for all body compartments. After significant weight loss no proportional bias was found for fat mass and percentage, although BIS systematically underestimated fat mass by 2.9 kg. Longitudinally, no proportional bias was found in the measured changes of absolute fat, fat-free mass and fat-free percentage between both methods, although BIS systematically underestimated fat and fat-free mass by 2.6 and 0.7 kg, respectively. Conclusion While BIS and DEXA are not interchangeable at baseline, the agreement between the two improved after significant weight loss. Proportional changes in fat mass, fat-free mass and fat-free percentage were similar for both techniques. BIS is a viable alternative to DEXA for future paediatric obesity studies measuring treatment effect at group levels, but is not superior to DEXA and cannot be used for monitoring individual changes due to wide limits of agreement.Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek (FWO-TBM 150179, FWO-TBM 150179)
This publication has 46 references indexed in Scilit:
- Comparison of DXA and water measurements of body fat following gastric bypass surgery and a physiological model of body water, fat, and muscle compositionJournal of Applied Physiology, 2010
- Pediatric reference data for lean tissue properties: density and hydration from age 5 to 20 yThe American Journal of Clinical Nutrition, 2010
- Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid BalanceBlood Purification, 2009
- Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgeryClinical Nutrition, 2008
- Body composition in male elite athletes, comparison of bioelectrical impedance spectroscopy with dual energy X-ray absorptiometryJournal of Negative Results in BioMedicine, 2008
- Body fluid volume determination via body composition spectroscopy in health and diseasePhysiological Measurement, 2006
- Body composition, as assessed by bioelectrical impedance spectroscopy and dual‐energy X‐ray absorptiometry, in a healthy paediatric populationActa Paediatrica, 2002
- Impact of hydration status on body composition as measured by dual energy X-ray absorptiometry in normal volunteers and patients on haemodialysisBritish Journal of Radiology, 1992
- Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXAMedical Physics, 1992
- A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part IClinical Chemistry and Laboratory Medicine (CCLM), 1983